Yvib Firmware Changes; Yvibs1B Firmware Enhancements; Vibration Monitoring Application Examples; Input Processing - GE Mark VIeS System Manual

Functional safety systems for general market
Hide thumbs Also See for Mark VIeS:
Table of Contents

Advertisement

8.3.2.8 YVIB Firmware Changes

The following is a list of changes made to the YVIBS1B with firmware V05.01 and later.
VibProx-KPH is renamed to VibProx-KPH1, to reflect that it uses KPH1 as source for 1x/2x tracking filters.
LM Accelerometers are supported for Inputs 4-8, without computation of LM Tracking Filters.
LM Tracking Filter refactored as -36 dB/oct Butterworth Filters.
LM 1x Tracking Filters are recomputed as 6-pole filters with the correct cutoff points.
ToolboxST Component Editor, Tab 'Gap 9-12' is renamed 'Gap 9-11' to reflect GAP12_POS4 becoming a possible
Keyphasor input.
New Parameters added to configure CDM Sensors.
N28 Low power now affects Velomitor and CDM Bently Nevada Charge Amp health.
Sensor out of range and Open circuit conditions hold input health low for 3 seconds after recovery.
Default Sensor Gains and Offsets are changed, as an example: Prox biasing is -9 V dc by default, not -10 V dc. This is
because the default bias value of 9 has been optimized for signal input range of +1 to -19 volts instead of optimizing for
the actual BN sensor 50 ml setting.
YVIB does not support mixed TMR module operation with YVIBS1Bs

8.3.2.9 YVIBS1B Firmware Enhancements

The following is a list of functional improvements made to the newer versions of YVIB.
LM Tracking Filters are computed for Velomitor, Seismic, and CDM sensors for inputs 1-3 in the S1B only.
Wideband Filters support 10-Pole Filters in the SIB only.
Input passband increased from 1150 Hz to 4500 Hz with S1B only.

8.3.3 Vibration Monitoring Application Examples

The YVIB module supports a variety of sensor types and applications. Refer to the tables Supported Sensor Inputs and Signal
Space Inputs for Sensor Types for the relevant I/O pack for valid sensor inputs and modes.
8.3.3.1 Position
Inputs 1-13 support Proximitor sensors to collect air gap value. In Heavy Duty turbine applications, Proximitors are used to
monitor the position of a rotating shaft. Position algorithms report a filtered air gap value.

Input Processing

The signal space values GAPn_VIBn, GAPn_POSy, GAPn_KPH# are the filtered engineering units (EU) values.
Gap values are filtered through a 2-pole, low-pass filter with a fixed cutoff frequency of 8 Hz. The output of the gap filter is
passed through a rolling average filter prior to scaling. Gap Values are converted from Volts to EU. For Position applications,
Gap values have a Scale Offset parameter Scale_Off applied after scaling.
Gap
V
PROX
Filter
In this application example, SysLim1GAPn, SysLim2GAPn provide System Limit status for GAPn_VIBn value as
True/False.
YVIB Vibration Monitor Modules
V
V
FILT
GAP
Mvg
Avg
A
Filter
Scale(V/EU)
Public Information
EU
GAP
A/B
A - B
A
B
B
Scale Offset(EU)
GEH-6855_Vol_II System Guide 243
GAPn_VIBn
GAPn_POSy
GAPn_KPH#