08/2005
Action log settings:
− Write interval file (logging frequency in seconds), default: 1
− File size of log file, default: 4 MB
− Path for log file (path entry)
− Logged alarms:
The alarms entered here (entered by their alarm number, separated by
commas) directly trigger the current action log to be saved to the hard disk.
9012
ACTION_LOG_MODE
MD number
Action log settings
Default value: 254
Changes effective after POWER ON
Data type: DWORD
Meaning
This MD can be used to enable/disable the action log and to define a
choice of the data to be logged.
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
Min. input value: 0
Protection level (R/W) 2/2
Applies from version 5.2
= 1
Action log ON (default)
= 0
Action log OFF
= 1
HMI Advanced: Variable services (write accesses
to geometric data) are logged.
For the meaning of variables refer to the help texts in
the Parameters operating area under variable views
(default).
= 0
Variable services are not logged.
= 1
HMI Advanced: PI services (e.g., program selection)
are logged; for meaning of variables,
refer to Help in the Parameters operating area under
Variable views (default)
= 0
PI services are not logged.
= 1
HMI Advanced: Domain services (e.g. load/unload
program) are logged (default)
= 0
Domain services are not logged.
= 1
Changes in the alarm status are logged
(default)
= 0
Changes in the alarm status are not logged
= 1
Key actuations are logged, Shop Mill,
SpTurn, ManualTurn only (default),
not in HMI Advanced
= 0
Key actuations are not logged.
= 1
Channel status/override is logged (default)
= 0
Channel status/override is not logged.
= 1
HMI Advanced: Softkey actuation and menu change
are logged. For Siemens internal use only (default)
= 0
Softkey actuations and menu changes are not
logged.
Commissioning HMI Advanced (IM4)
4 Diagnostics
Max. input value: 0xffff
Unit: -