Starting Up HMI Embedded (IM2)
4 Functions/Parameterization
The language displayed during the control ramp-up is set via the MD 9003 display
machine data. FIRST_LANGUAGE
4.2.4

Activating / deactivating calculator help

Via the display machine data MD 9991: HMI_HELP_SYSTEMS can be used to
activate/deactivate the calculator help.
Bit 0 = 0 help display not active
Bit 0 = 1 help display active (default setting)
4.2.5

Setting date / time

You can set the date and time in the PLC and synchronize the PLC and HMI
Embedded date and time.
This function is accessed via the Startup operating area in the PLC menu by
activating the "Set time/date" softkey.
If any changes are made to the time and date, the time and date from HMI
Embedded are transferred to the PLC.
The synchronization can be verified in the "Current time:" output field.
The cyclical synchronization of the time can be
activated/deactivated via the "Synchronous AUTO/ON" or "Synchronous
AUTO/OFF" softkeys and
the duration of the synchronization set via the "Synchronous manual" softkey.
10 minutes should be entered as default.
Minimum value: 0, maximum value: 99.
The set values are retained when the control is rebooted.
Note
Changes can only be made to the PLC operands with the appropriate password.
IM2/4-38
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition