08/2005
Fig. 4-3
Detailed view
Click the area of interest with the cursor and select the "Details" softkey. The
current data for the relevant machine data are then displayed.
The block header contains the number and name of the machine data. The
currently set values are output on the lines below.
You can change the memory setting in the gray field after "New value" or "New
number" to the right of the field containing the actual value.
This new setting is entered temporarily. Your entry is automatically checked for
limits and an appropriate message output in the dialog line if you make a mistake.
The total available memory, taking into account any modified values, is displayed in
the lower half of the screen.
The "Axis+" and "Axis-" softkeys are displayed for axis-specific machine data.
The "Channel+" and "Channel-" are softkeys displayed for channel-specific
machine data.
When you select the "Accept" softkey, the temporary values of the displayed
machine data are transferred to the NC.
You can exit the detail view by selecting the "Cancel" softkey or the Recall key "^".
Note
Once you have pressed "Accept" softkey, the "Cancel" softkey is no longer
operative, i.e., any changes you have made cannot be undone.
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D HMI Installation and Start-Up Guide (IAM) – 08/2005 Edition
Static user memory SRAM
Starting Up HMI Embedded (IM2)
4 Functions/Parameterization
IM2/4-61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810dSinumerik 840diSinumerik 840d

Table of Contents