08/2005
Note
• Empty positions need not be specified.
• Predefined status displays can be disabled in the HEADER.INI file in the OEM
or USER directories with the value <empty>, e.g.,
ChanStatFeedStopSpindleStop = <empty>.
• The complete HEADER.INI file is reproduced in Section 3.7.
16 display positions
There are 16 display positions defined in the program status line (header), where
each SINUMERIK icon occupies two positions: number + icon.
Figure 2-1
The SINUMERIK icons are permanently assigned to an output position. A section
is created in the HEADER.INI configuration file for each position used.
Sample view of the program status line with SINUMERIK icons for 4 channels and
2 spindles:
Figure 2-2
These displays always have the predefined channel or spindle number.
Example:
The status displays for 2 channels and 1 spindle should always be output at the
first, third and fifth display position.
HEADER.INI file:
[Pos1]
ChanStatFeedStopSpindleStop = 3
Spindles = 1,2
[Pos3]
ChanStatFeedStop = 2 ; channel status of channel 2 is displayed
[Pos5]
SpindStat= 3
© Siemens AG, 2005. All rights reserved
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
1 2 3 4 5 6 7 8 9 10 11 12 13 1415 16
1 2 3 4 5 6 7 8 9 10 11 12 13 1415 16
1
; first display position
; channel status of channel 3 is displayed,
; superimposed with feed disable for channel 3 and
; spindle disable for spindles 1 and 2
; third display position
; superimposed with feed disable for channel 2
; fifth display position
; spindle status for spindle 3 is displayed
Commissioning HMI Advanced (IM4)
2 Setting Functions and Parameters
S1
S2
IM4/2-29