Commissioning HMI Advanced (IM4)
2 Setting Functions and Parameters
Setting the search configuration
The various configurations are activated by means of the MACHINE.INI file.
The following entries are possible in the [BlockSearch] section:
[BlockSearch]
SeruproConfig
=1
=2
=3
=4
Changes take effect immediately, i.e., with the next search.
Deactivating function
The following entries are possible in the [BlockSearch] section:
[BlockSearch]
SeruproEnabled
Changes take effect immediately, i.e., with the next search.
2.1.5 Configurable Displays in the Header
Using the PLC, it is possible to configure a two-line text display to appear in the
"Program name" field in the header of JOG and MDA modes (e.g., selected slide,
activated handwheel) See also Alarm Display.
Text length
The maximum length of the texts to be displayed is 30 characters per line.
Syntax
The texts can consist of:
• A language-specific part (from alarm/message text file *.COM)
• Three parameters (%1, %2, %3)
User PLC-DB
The display must be configured via a user PLC-DB.
• The number of the DBx with DBBy must be entered by the user in the
HEADER.INI file as follows:
[UserTextInfo]
USER_TEXT_BASE=DBx.DBBy
where x = data block number, y = start byte in the block.
IM4/2-22
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
Block search in currently selected channel (default)
Block search in currently selected channel and in all
channels with the same workpiece
Block search in currently selected channel and in all
channels with the same mode group
Block search in all channels
=0
Function inactive
=1
Function active (default)
© Siemens AG, 2005. All rights reserved
08/2005