Siemens SINUMERIK 840D sl Commissioning Manual page 468

Commissioning cnc part 2 (hmi)
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Commissioning HMI Advanced (IM4)
2 Functions/Parameterization
Table 2-6
Parameters for the text file
FileName.com
File name_XX.com
(XX=language code, e.g. "gr" for
German. For a list of language
codes, see also /IAD/840D
Installation and Start-Up Guide,
Section "Alarm and Message
Texts")
Filename_.com
Example: ENDUSER=CUS.DIR\IFM_.COM
First of all, the non-language-specific text file "Ifm.com" is opened in the path
"C:\DH\CUS.DIR\" by default or, if the non-language-specific text file does not exist,
the relevant language-specific text file (e.g. "IFM_GR.COM") is opened.
Extract from Short Help txt file "IFM_GR.COM":
...
a2//G00/Linear interpolation with rapid traverse (m)
a2//G01/Linear interpolation with feed (m)
a2//G02/Circular interpolation in clockwise direction (m)
...
CONTEXT section
An increased context sensitivity of the Help function can be selected in the
[CONTEXT] section. This setting is activated with "1" and deactivated with "0".
(Also entered under "Settings").
If the increased context sensitivity is activated and the cursor is positioned to the
left of, next to or on an instruction text, then all instructions with the same initial
letters are displayed when Help is called.
For example, if the programmer has selected instruction "G1", then all instructions
beginning with "G1" (e.g. "G1", "G17", "G18", "G19") are displayed.
If increased context sensitivity has been deactivated with "0", then only the
instruction actually selected (if available) is displayed.
TEXTSEARCH section
The text search type can be specified in the [TEXTSEARCH] section. The following
search methods can be parameterized:
1 = instruction texts only
2 = descriptive texts only
3 = instruction and descriptive texts
(Also entered under "Search").
IM4/2-74
SINUMERIK 840D sl/840D/840Di/810D Installation and Start-Up HMI (IAM) - 08/2005 Edition
Interpretation
The language-dependent text file is read out.
The language-specific text file is read out.
In this setting the non-language-specific test
file is read first, if present, otherwise the
language-specific text is read.
© Siemens AG, 2005. All rights reserved
08/2005

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810dSinumerik 840diSinumerik 840d

Table of Contents