Installation Procedures; General - Nokia 7360 Intelligent Services Access Manager FX Series Hardware Installation Manual

Ansi
Hide thumbs Also See for 7360 Intelligent Services Access Manager FX Series:
Table of Contents

Advertisement

Installing cards in the 7360 ISAM FX-8 shelf

15.6 Installation procedures

This section describes the following card installation procedures:
15.6.1
When installing cards in a new installation, install the NTIO card first. Allow the NT
IO card to initialize and come into service before installing NT or LT cards. When
replacing an LT card, verify that the NT card is in service before inserting the LT card.
The NT and LT dummy panels (or dummy front panels) must be installed in any
unused, unpopulated NT or LT card slot in order to maintain proper operation. Filler
plate units have no electronic components; they are mechanical units used to provide
ESD/EMI seal and thermal seal in the 7360 ISAM FX-8.
288
To install NTIO cards
To install NT cards
To install LT cards
To remove cards
To change the NGFC-H card
For the 7360 ISAM FX-8, installation of NTIO cards
Warning —
must be performed prior to installation of NT cards.

General

Unplugging and reseating the active NT card in
Warning —
less than 3 seconds may result in an approximately 1 minute
service interruption while the NT cards negotiate active/
standby state during initialization. Wait at least 5 seconds
before reseating an unplugged active NT card.
Redundant NT cards must be provisioned first before
Note 1 —
they are installed. See the appropriate product Operations and
Maintenance Guide to configure an NT card and to configure
NT redundancy.
The following steps must be followed if the NTIO
Note 2 —
board (FNIO-A) is moved to a new shelf:
plan the NTIO board in the new shelf
reset the shelf
plug in the NTIO board
See Operations and Maintenance Guide for FD 100/320 Gbps
NT and FX NT for planning information.
3HH-12893-AAAA-TCZZA