7360 ISAM FX-8 shelf cabling
The 7360 ISAM FX-8 requires a 50-pin micro DSUB connector with an angled head
for the CO external alarm connection. A cable assembly is available from Nokia (sold
separately), that can be used with the 7360 ISAM FX-8, as shown in Figure 141. See
Figure
Figure 141
CO external alarm cable for 7360 ISAM FX-8
Supplier
label
For a description of the CO external alarm connector pinning, see your Nokia
representative.

14.7 BITS interface connections

The 7360 ISAM FX-8 requires six wire-wrappable pins for the BITS clock timing
connection. BITS timing signals will be supplied using two twisted pair cables (22
AWG solid copper conductors with overall shield and drain wire, Belden 1175A or
equivalent). One cable will connect to the 3 wire-wrap pins for NT-A, and the other
will connect to the 3 wire-wrap pins for NT-B.
See Figure
For a description of the BITS interface pinning, see Appendix 25.
270
140
for the location of the CO external alarm connector.
Company
label
Connect the drain wire (FG) at one end only, either at
Note —
the 7360 ISAM FX-8 or at the source.
140
for the connection location.