Figure 198 External Interfaces On 7360 Isam Fx-4; Co External Alarm Connector - Nokia 7360 Intelligent Services Access Manager FX Series Hardware Installation Manual

Ansi
Hide thumbs Also See for 7360 Intelligent Services Access Manager FX Series:
Table of Contents

Advertisement

ANSI Hardware Installation Manual
9
10
Procedure 78
Use the following procedure when the power cables need to be disconnected on 7360 ISAM FX-4.
1
2
3
4

18.6 CO external alarm connector

Figure
Figure 198
The 7360 ISAM FX-4 requires a 50-pin micro DSUB connector with an angled head
for the CO external alarm connection. A cable assembly is available from Nokia (sold
separately), that can be used with the 7360 ISAM FX-4, as shown in Figure 199. See
Figure
Issue: 09
Verify that the fans spin.
STOP. This procedure is complete.
To disconnect the power cables
Warning — If the following sequence is not followed exactly, there can
be a possible fire hazard.
Before disconnecting the power cables, ensure that power to the cables have been
disconnected.
Disconnect the battery cables BAT A and BAT B
Disconnect the BATRET cables RET A and RET B
STOP. This procedure is complete.
198
shows the external interfaces on the 7360 ISAM FX-4 shelf.
External interfaces on 7360 ISAM FX-4
External Alarms
N594
198
for the location of the CO external alarm connector on the GFC card.
3HH-12893-AAAA-TCZZA
BITS
TOD/IHZ
NTA GND NTB
DRAFT
7360 ISAM FX-4 shelf cabling
Remote Craft
BAT A
21955
353