SmartLogger2000
User Manual
Figure 7-52 Setting NetEco parameters
7.10.2.5 Setting Modbus TCP Parameters
Set Modbus TCP parameters for the SmartLogger to communicate with a third-party NMS.
Because of permission restriction, log in as Advanced User or Special User. Choose
Settings > Modbus TCP to access the target page.
Issue 04 (2018-04-10)
NetEco server: Set the IP address or domain name of the NetEco server, or select the server in the
drop-down list box. When selecting the server in the list box, the NetEco parameter settings will be
automatically displayed.
When the SmartLogger connects to the Huawei NMS, retain the default value 16100 for Port
number. When the SmartLogger connects to the third-party NMS, set Port number according to
the server port enabled in a third-party NMS.
In most cases, set Address mode to Comm. Address. If the devices connected to the six RS485
ports of the SmartLogger have duplicate communications addresses, you must set Address mode to
Logical address.
If SSL encryption is set to Disable, data will be transmitted without being encrypted, which may
result in user data theft. Therefore, exercise caution when deciding to set SSL encryption to
Disable.
If Second challenge authentication is set to Disable, the second challenge authentication result will
not be verified, which may result in user data theft. Therefore, exercise caution when deciding to set
Second challenge authentication to Disable.
Obtain the documents about security certificate from the NMS.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7 WebUI
155