Step 4 Determine the operating status based on the Ethernet optical port indicators.
Figure 4-29 Ethernet optical port indicators
Table 4-7 Ethernet optical port indicator description
Indicator
(1) Upper port
(2) Lower port
----End
Follow-up Procedure
Disconnection can be performed in reverse order.
Issue 04 (2018-04-10)
Status
Green and yellow off
Green steady on and blinking yellow at
short intervals (0.1s on and 0.1s off)
Green steady on and yellow blinking
intermittently
Green steady on and blinking yellow at
long intervals (0.1s on and 1.9s off)
1. When removing a fiber jumper, press down the clip first.
2. When removing an optical module, press down the handle and pull the module outwards.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Electrical Connection
Meaning
No optical module is
inserted into the Ethernet
optical port.
The fiber link is being set
up.
The data is being
transmitted.
The fiber link is normal.