7.11.8 Device Management

7.11.8.1 Connecting Devices

Because of permission restriction, log in as Advanced User or Special User. Choose
Maintenance > Connect Device to access the target page.
Figure 7-78 Connecting devices
Issue 04 (2018-04-10)
Ensure that the extension of the license file to be imported is .dat or .zip.
If the SmartLogger communicates with the inverter over PLC, set Built-in PLC to Enable after the
parameters are set. If the SmartLogger communicates with the inverter and third-party devices over
RS485 only, set Built-in PLC to Disable. For details, see
Huawei devices can be automatically recognized and connected or manually added. EMIs, electricity
meters, slave SmartLoggers, and third-party devices cannot be automatically recognized and must be
manually added.
If the devices connecting to different RS485 ports on the SmartLogger have address conflict (such as
COM1-1 and COM2-1), and the SmartLogger is communicating with a Huawei or third-party NMS,
set Address mode to Logical address. For details, see
7.10.2.5 Setting Modbus TCP
connecting to each RS485 port has a unique address.
Before manually adding an EMI connected over the COM port, set RS485 parameters correctly by
following the instructions in
Connection mode to Modbus-RTU when adding the EMI. Before manually adding an EMI
connected over the AI/PT port, you do not have to set RS485 parameters. You only have to set
Device Type to EMI and Connection mode to AI when adding the EMI. After adding an EMI
manually, correctly set the EMI parameters. For details, see
Before manually adding the Modbus or DL/T645 electricity meter, set RS485 parameters correctly
by following the instructions in
Modbus electricity meter, correctly set the electricity meter parameters. For details, see
Setting Power Meter
Parameters. When adding an electricity meter, set Device Type to Power
Meter and Comm.protocal to the protocol supported by the electricity meter.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7.10.2.4 Setting NetEco Parameters
Parameters. If you do not set the parameter, ensure that the device
7.10.2.2 Setting RS485
Parameters. Then set Device Type to EMI and
7.10.2.2 Setting RS485
Parameters. Before manually adding the
7.10.2.2 Setting RS485
Parameters.
7.8.5.2 Setting Running
Parameters.
7 WebUI
and
7.10.2.3
179