Figure 4-16 Connecting the SmartLogger to a split EMI (1)
Step 1 Prepare a cable with an appropriate length, strip a proper part of the insulation layer from one
end, and connect the end to the port on the analog-to-digital converter.
Step 2 Connect the other end of the cable to the COM port of the SmartLogger. For details, see
Connecting Cables to the Terminal Block on the COM
When connecting cables, ensure that the RS485+ and RS485– ports on the analog-to-digital
converter respectively connect to the COM+ and COM– ports on the SmartLogger.
Step 3 The Baud Rate settings for the analog-to-digital converter and SmartLogger must be the
same.
Step 4 Connect each sensor to the analog-to-digital converter. For detailed operations, see the
documents delivered with the analog-to-digital converter or sensors.
Issue 04 (2018-04-10)
The DJYP2VP2-22 2x2x1 computer cable or a communications cable with a conductor
cross-sectional area of 1 mm
For detailed operations, see the document delivered with the analog-to-digital converter.
For SmartLogger communication parameter settings, see
Parameters
or the SUN2000 APP User Manual.
For details about the communications parameter configurations for the analog-to-digital
converter, see the delivered document.
The EMI cannot be automatically identified. After connecting cables, log in to the embedded WebUI
and manually add the EMI. For details, see
and Connection mode to Modbus-RTU.
After adding an EMI, set its parameters. For details, see
Setting Running
Parameters. The EMI model is Sensor(ADAM).
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2
and outer diameter of 14–18 mm is recommended.
Port.
7.11.8.1 Connecting
Connection over the COM Port
4 Electrical Connection
7.10.2.2 Setting RS485
Devices. Set Device Type to EMI
in
7.8.5.2
4.3
59

Advertisement

Table of Contents
loading

Table of Contents