Huawei SmartLogger2000 User Manual page 19

Hide thumbs Also See for SmartLogger2000:
Table of Contents

Advertisement

SmartLogger2000
User Manual
Bottom of the Shell
Figure 2-4 SmartLogger2000-10/10-B/11-B bottom
Table 2-2 Port description
No.
Port (Silk Screen)
1
RF1, RF2
2
12V OUT
3
12V IN
4
USB
5
SFP1, SFP2
6
ETH1, ETH2
7
DO
8
COM1–COM6
9
Default
10
AC1, AC2
11
Issue 04 (2018-04-10)
Function
Reserved
12 V DC output
12 V DC input
USB port
Ethernet optical port
Ethernet electrical port
Digital parameter output
RS485 communication
Default key
AC power cable ports
External grounding
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
Reserved.
Provides 12 V DC power supply with a
maximum current of 100 mA.
Connects to a power adapter.
Connects to a USB flash drive.
Connects to an Access Terminal Box
(ATB) or another cascaded SmartLogger.
Connects to an Ethernet switch, router,
POE module, or PC.
Relay output; supports the voltage of 12 V
and current of 0.5 A.
Six RS485 ports that can be connected to
devices such as the inverter, box-type
transformer, electricity meter, or EMI
Resets and restarts the Bluetooth module
or resets the SmartLogger IP address to
a
the default IP address
. The default IP
address is 192.168.0.10.
SmartLogger2000-10/10-B: Connects
to the A, B, and C three-phase inputs,
and used for PLC with the SUN2000
over AC power cables. If PLC function
is not used, you do not have to connect
cables to these ports.
SmartLogger2000-11-B: disabled
N/A
2 Product Overview
9

Advertisement

Table of Contents
loading

Table of Contents