ABB IRC5 Compact Product Manual page 142

Hide thumbs Also See for IRC5 Compact:
Table of Contents

Advertisement

4 Repair
4.16.1 Replacement of power distribution board
Continued
Removal
Use this procedure to remove the power distribution board.
1
2
3
4
5
6
7
8
Continues on next page
142
Action
DANGER
Before commencing any work inside the
cabinet, please observe the safety in-
formation in section
DANGER - Make
sure that the main power has been
switched off! on page
29.
CAUTION
Hot surface on top of the power distribu-
tion board unit.
Risk of burns. Be careful when removing
the unit.
Remove the top cover of the cabinet.
Remove the left and right side covers of
the cabinet.
Lift the middle layer of the cabinet and
secure it.
Disconnect all connectors from the
power distribution board.
Remove the attachment screws.
Lift the power distribution board straight
up.
© Copyright 2009-2013 ABB. All rights reserved.
Note/illustration
See
Lifting the middle layer on page
See
Removing the top cover on page
See
Removing the left side cover on page 67
and
Removing the right side cover on
page
68.
See
Lifting the middle layer on page
B
xx0900000549
A: power distribution board
B: attachment screws
3HAC035738-001 Revision: E
69.
67.
69.
A

Hide quick links:

Advertisement

Table of Contents
loading