Replacement Of System Fans - ABB IRC5 Compact Product Manual

Hide thumbs Also See for IRC5 Compact:
Table of Contents

Advertisement

4 Repair

4.13 Replacement of system fans

4.13 Replacement of system fans
Location
The following illustration shows the location of the system fans.
xx0900000502
A
B
Required equipment
Equipment
Fan with receptacle
Removal
Use this procedure to remove one of the system fans.
1
2
Continues on next page
134
System fan
Fan cover
Action
DANGER
Before commencing any work inside the cabinet, please observe the safety information
in section
DANGER - Make sure that the main power has been switched off! on page
CAUTION
Hot surface on top of the bleeder. Risk of burns. Be careful when removing the unit.
© Copyright 2009-2013 ABB. All rights reserved.
Note
See
Miscellaneous parts on page
3HAC035738-001 Revision: E
160.
29.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents