● Code :
A3-2110
● Symptom / Cause :
Calibration for density sensor is failed
● Troubleshooting method :
1. Check if the driving section of the developer is opera
2. Enter the Service mode. Check the TC value.
(Diagnostics > Engine Diagnostics > Engine Test Ro
3. If TC value is not proper range. (TC Value : 80~12
- Replace the imaging unit.
● Replacement part
K Imaging Unit : CLT-R607K
g g
C Imaging Unit : CLT-R607C
M Imaging Unit : CLT-R607M
Y Imaging Unit : CLT-R670Y
Service Manual
CLX-9250/9350 series
7. Troubles
shooting
● Error message :
Actuator Sensor Fail
lure #A3-2110: Turn off then on.
ated properly.