Samsung CLX-9350ND Service Manual page 264

Digital color laser mfp
Hide thumbs Also See for CLX-9350ND:
Table of Contents

Advertisement

Code
NVM Description
Charger Clean Reference
105-0250
Cycle for Enviroment5
Charger Clean Reference
105-0260
Cycle for Enviroment6
Charger Clean Reference
Charger Clean Reference
105-0270
Cycle for Enviroment7
Charger Clean Reference
105-0280
Cycle for Enviroment8
Stand-By Temperature
109-0010
Offset
Low Power Temperature
109-0020
Offset
Thin(60~70gsm)
109-0030
Temperature offset
Plain(70~90gsm)
109-0040
Temperature offset
Thick(90~105gsm)
109-0050
Temperature offset
Heavy(106~175gsm)
109-0060
Temperature offset
Extra Heavy1
Extra Heavy1
109-0070
(176~216gsm)
Temperature offset
Extra Heavy2
109-0080
(217~253gsm)
Temperature offset
Recycled paper(70~90gsm)
109-0090
Temperature offset
Temperature offset
Transparency Temperature
109-0150
offset
Envelopes Temperature
109-0170
Offset
109-0180
Labels Temperature offset
Service Manual
CLX-9250/9350 series
4.Servic
ce Mode
Meaning
Reference C
Cycle to clean charger in
Environmen
nt 5
Environme
ent 4~6 : NN Condition
(Normal Tem
mp (~28℃/82℉),
Normal Hum
midity(~73%))
Reference C
Cycle to clean charger in
Environmen
nt 6
Environme
ent 4~6 : NN Condition
(Normal Tem
mp (~28℃/82℉),
Normal Hum
midity(~73%))
Reference C
Cycle to clean charger in
Environmen
nt 7
• Environme
ent 7~8 : HH Condition
(High Temp
(more than 28℃/82℉ ),
High Humid
ity(more than 73% ))
Reference C
Cycle to clean charger in
Environmen
nt 8
Environme
ent 7~8 : HH Condition
(High Temp
(more than 28℃/82℉ ),
High Humid
High Humid
ity(more than 73% ))
ity(more than 73% ))
Target Tem
perature during standby
mode.
Target Tem
perature during
Power save
mode.
Target Tem
perature for thin
paper.
Target Tem
perature for plain
paper.
Target Tem
perature for thick
paper.
Target Tem
perature for heavy
paper.
Target Tem
perature for extra
heavy1 pape
er.
Target Tem
perature for extra
heavy2 pape
er.
Target Tem
perature for Recycled pa
per
per.
Media type o
offset for fuser roll
temperature
e.
Media type o
offset for fuser roll
temperature
e.
Media type o
offset for fuser roll
temperature
e.
4-1
15
Default
Max/Min
10,000
90000
/300,000
10,000
60000
/300,000
10,000
10 000
60000
/300,000
10,000
60000
/300,000
0
2/-2
0
2/-2
0
2/-2
0
2/-2
0
2/-2
0
2/-2
0
2/-2
0
2/-2
0
2/-2
0
2/-2
0
2/-2
0
2/-2
SAMSUNG ELECTRONICS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clx-9250nd

Table of Contents