SmartLogger2000-(10-C, 11-C)
User Manual
7.7.7.2 Setting Running Parameters
Because of permission restriction, log in as Advanced User. Choose Monitoring > PID >
Running Param. to access the target page.
Figure 7-37 Setting running parameters
Table 7-9 Parameter description
No
Paramet
Function
.
er
1
Offset
Specifies the
mode
offset mode of the
PID module.
Issue Draft A (2017-02-15)
You can click the
tab on the tertiary navigation menu to query PID module-related information.
Performance data of the PID module can be exported. When changing the name of the exported file,
retain the extension .tar.gz. Otherwise, the file will be unusable.
Value
Disabled
N/PE
PV/PE
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
,
Description
Select Disabled if the PID module is not required.
PID01: Select N/PE if the PID module is required to
use voltage output from the inductor virtual midpoint.
SmartPID2000: Select N/PE if the PID module is
required to use voltage output from the power grid.
PID01: Select PV/PE if the PID module is required to
use voltage output from the negative PV terminal. This
mode is applicable only to Huawei SUN8000.
SmartPID2000: N/A
7 WebUI
,
, or
120