5. PARAMETERS
(2) Details list
Class No. Symbol
0
*STY
Control mode, regenerative brake option selection
Used to select the control mode and regenerative brake option.
1
*OP1
Function selection 1
Used to select the input signal filter, the function of pin CN1-12.
Name and function
Select the control mode.
0:Position
1:Position and internal speed
2:Internal speed
Motor series selection
0:HC-KFE
1:HC-SFE
Selection of regenerative brake option
0:Not used
(The built-in regenerative brake resistor used.)
2:MR-RB032
3:MR-RB12
4:MR-RB32
5:MR-RB30
6:MR-RB50
Motor capacity selection
0:100W
1:200W
2:400W
3:500W
4:750W
5:1kW
6:1.5kW
7:2kW
POINT
Wrong setting may cause the regenerative brake option to burn.
If the regenerative brake option selected is not for use with the
servo amplifier, parameter error (AL.37) occurs.
0
0
Input signal filter
If external input signal causes chattering
due to noise, etc., input filter is used to
suppress it.
0:None
1:1.777[ms]
2:3.555[ms]
3:5.333[ms]
CN1-12 function selection
0:Zero Speed detection signal
1:Electromagnetic brake interlock signal
5 - 5
Initial
Setting
Control
Unit
value
range
100W
Refer to
: 0000
Name
and
200W
function
: 1000
column.
400W
: 2000
750W
: 4000
1kW
: 5010
2kW
: 6010
0002
Refer to
Name
and
function
column.
mode
P S
P S