Mitsubishi Electric GENERAL PURPOSE AC SERVO MR-E- A/AG Instruction Manual page 269

General-purpose ac servo
Table of Contents

Advertisement

15. MR-E-
AG SERVO AMPLIFIER COMPATIBLE WITH ANALOG INPUT
(3) Speed/torque control change mode
Set "0003" in parameter No. 0 to switch to the speed/torque control change mode.
(a) Control change (LOP)
Use control change (LOP) to switch between the speed control mode and the torque control mode
from an external contact. Relationships between LOP and control modes are indicated below:
(Note) LOP
0
Speed control mode
1
Torque control mode
Note.0: off
1: on
The control mode may be changed at any time. A change timing chart is shown below:
Control change (LOP)
Servo motor speed
Analog torque
command (TC)
Note: When the start (ST1 ST2) is switched off as soon as the mode is changed to speed control,
the servo motor comes to a stop according to the deceleration time constant.
(b) Speed setting in speed control mode
Same as (1)(a).
(c) Torque limit in speed control mode
Same as (1)(c).
(d) Speed limit in torque control mode
Same as (2)(c).
(e) Torque control in torque control mode
Same as (2)(a).
(f) Torque limit in torque control mode
Same as (2)(b).
Servo control mode
Speed
control mode
ON
OFF
10V
0
Torque
Speed
control mode
control mode
(Note)
Load torque
Forward rotation in driving mode
15 - 24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-e-*aMr-e-*agMr-e- a seriesMr-e- ag series

Table of Contents