5. PARAMETERS
Class No. Symbol
44
*DI3
Input signal selection 3 (CN1-3)
Allows any input signal to be assigned to CN1-pin 3.
The assignable signals and setting method are the same as in input
signal selection 2 (parameter No. 43).
0 0
This parameter is unavailable when parameter No. 42 is set to
assign the control change (LOP) to CN1-pin 3.
This parameter is unavailable when parameter No. 48 is set to
assign the Forward rotation stroke end (LSP) and Reverse rotation
stroke end (LSN) to be assigned to CN1-pin 3.
Input signal selection 4 (CN1-5)
45
*DI4
Allows any input signal to be assigned to CN1-pin 5.
The assignable signals and setting method are the same as in input
signal selection 2 (parameter No. 43).
0 9
This parameter is unavailable when parameter No. 42 is set to
assign the control change (LOP) to CN1-pin 5.
This parameter is unavailable when parameter No. 48 is set to
assign the Forward rotation stroke end (LSP) and Reverse rotation
stroke end (LSN) to be assigned to CN1-pin 5
Input signal selection 5 (CN1-6)
46
*DI5
Allows any input signal to be assigned to CN1-pin 6.
The assignable signals and setting method are the same as in input
signal selection 2 (parameter No. 43).
0 0
This parameter is unavailable when parameter No. 42 is set to
assign the control change (LOP) to CN1-pin 6.
This parameter is unavailable when parameter No. 48 is set to
assign the Reverse rotation stroke end (LSN) to be assigned to CN1-
pin 6.
Name and function
Position
Input signals of
control mode
CN1-pin 3
Internal speed
selected.
control mode
Position
Input signals of
control mode
CN1-pin 5
Internal speed
selected.
control mode
Position
Input signals of
control mode
CN1-pin 6
Internal speed
selected.
control mode
5 - 17
Initial
Setting
Control
Unit
value
range
mode
0882
Refer to
Name
and
function
column.
0995
Refer to
Name
and
function
column.
0000
Refer to
Name
and
function
column.
P S
P S
P S