Analog Monitor, Rs-232C Branch Cable (Mr-E3Cbl15-P) - Mitsubishi Electric GENERAL PURPOSE AC SERVO MR-E- A/AG Instruction Manual

General-purpose ac servo
Table of Contents

Advertisement

13. OPTIONS AND AUXILIARY EQUIPMENT

13.1.3 Analog monitor, RS-232C branch cable (MR-E3CBL15-P)

(1) Usage
The analog monitor, RS-232C branch cable (MR-E3CBL15-P) is designed for use when a personal
computer and analog monitor outputs are used at the same time.
Servo amplifier
CN3
(2) Connection diagram
Analog monitor, RS-232C branch cable
(MR-E3CBL15-P)
Servo amplifier
Plate
SD
RXD
1
TXD
2
LG
3
MO1
4
MO2
6
Plate
SD
MO2
LG
MO1
LG
RS-232C
RXD
1
2
TXD
3
LG
Plate
SD
Analog monitor
LG
3
4
MO1
6
MO2
Plate
SD
13 - 19
Communication cable
(QC30R2)
Analog monitor output 2
Analog monitor output 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-e-*aMr-e-*agMr-e- a seriesMr-e- ag series