13. OPTIONS AND AUXILIARY EQUIPMENT
13.2.2 No-fuse breakers, fuses, magnetic contactors
Always use one no-fuse breaker and one magnetic contactor with one servo amplifier. When using a fuse
instead of the no-fuse breaker, use the one having the specifications given in this section.
Servo amplifier
No-fuse breaker
MR-E-10A
30A frame 5A
MR-E-20A
30A frame 5A
MR-E-40A
30A frame 10A
MR-E-70A
30A frame 15A
MR-E-100A
30A frame 15A
MR-E-200A
30A frame 20A
13.2.3 Power factor improving reactors
The input power factor is improved to be about 90%. For use with a 1-phase power supply, it may be
slightly lower than 90%.
W
RX S Y T Z
C
W1
Servo amplifier
Model
MR-E-10A/20A
FR-BAL-0.4K
MR-E-40A
FR-BAL-0.75K
MR-E-70A
FR-BAL-1.5K
MR-E-100A
FR-BAL-2.2K
MR-E-200A
FR-BAL-3.7K
Fuse
Class
Current [A]
K5
10
K5
10
K5
15
K5
15
K5
15
K5
15
[Unit : mm]
3-phase
200 to 230VAC
D1 5
Installation screw
1-phase
230VAC
Dimensions [mm (in) ]
W
W1
H
135 (5.31) 120 (4.72) 115 (4.53)
135 (5.31) 120 (4.72) 115 (4.53)
160 (6.30) 145 (5.71) 140 (5.51)
160 (6.30) 145 (5.71) 140 (5.51)
220 (8.66) 200 (7.87) 192 (7.56)
13 - 23
Magnetic contactor
Voltage [V]
S-N10
AC250
S-N18
NFB
NFB
D
D1
59 (2.32)
45 (1.77)
7.5 (0.29)
69 (2.72)
57 (2.24)
7.5 (0.29)
71 (2.79)
55 (2.17)
7.5 (0.29)
91 (3.58)
75 (2.95)
7.5 (0.29)
90 (3.54)
70 (2.76)
10 (0.39)
FR-BAL
Servo amplifier
MC
R
X
L
S
Y
L
T
Z
L
FR-BAL
Servo amplifier
MC
R
X
L
S
Y
L
T
Z
L
Mounting
Terminal
C
screw size
screw size
M4
M3.5
M4
M3.5
M4
M3.5
M4
M3.5
M5
M4
1
2
3
1
2
3
Weight
[kg (lb)]
2.0 (4.4)
2.8 (6.17)
3.7 (8.16)
5.6 (12.35)
8.5 (18.74)