Upgrading The Firmware Of An Acuix Dome - Honeywell Rapid Eye System Administration Manual

Hide thumbs Also See for Rapid Eye:
Table of Contents

Advertisement

Upgrading the Firmware of an ACUIX Dome

Document 800-07769 Rev A
02/11
4.
Select an ACUIX dome.
5.
Click Camera Menu. The model of the camera is listed.
1.
Run a
Maintenance
Session.
2.
On the Serial Devices tab, click the port to which the Intellibus device is assigned.
3.
Click Discover to update the table of ACUIX domes.
4.
Do one of the following:
Select all of the ACUIX domes, by clicking the checkbox at the top of the Name
column (see
Figure
Select some of the ACUIX domes. If you are not upgrading all of the ACUIX
domes, the cameras are upgraded one by one. See
5.
Click Firmware Upgrade. A standard file opening window appears, showing the
drives and folders available on the operator PC.
6.
Select a drive, folder and a firmware file for the ACUIX dome. These files should have
an *.ngd file extension.
7.
Click Open.
8.
A Maintenance Message dialog box appears to confirm your selection. Click Yes to
proceed.
9.
If there are many ACUIX domes connected to the unit, and all were selected in step 4
of this procedure, a Sequence for Upgrading Cameras dialog box appears. Select a
sequence, and then click Continue. The upgrade of the cameras can be:
Simultaneous. This will take approximately 10 minutes.
One by one. Being more time consuming, this procedure takes about 10 minutes
for each camera. This upgrade stops if a camera is off or if the connection fails. A
warning appears for that camera if the upgrade stops.
Caution
If you select Simultaneous, and an ACUIX dome is off, or the connection
fails, the upgrade appears to continue without warning the operator. Use
this procedure again when all of the ACUIX domes are powered and the
connection to them is operational.
Rapid Eye DVR System Administrator Guide
6-15).
of this procedure.
step 9
111