exec-timeout
Set a time interval the system will wait for input on a line before disconnecting the session.
C-Series, E-Series, S-Series, Z-Series
Syntax
exec-timeout minutes [seconds]
To return to default settings, use the no exec-timeout command.
Parameters
minutes
seconds
Defaults
10 minutes for console line; 30 minutes for VTY lines; 0 seconds
Command Modes
LINE
Command History
Version 8.3.11.1
Version 7.6.1.0
Version 7.5.1.0
E-Series
Usage
To remove the time interval, enter exec-timeout 0 0.
Information
Example
FTOS con0 is now available
Press RETURN to get started.
FTOS>
exit
Return to the lower command mode.
C-Series, E-Series, S-Series, Z-Series
Syntax
exit
Command Modes
Enter the number of minutes of inactivity on the system before
disconnecting the current session. Range: 0 to 35791. Default: 10
minutes for console line; 30 minutes for VTY line.
(OPTIONAL) Enter the number of seconds Range: 0 to 2147483.
Default: 0 seconds.
Introduced on the Z9000.
Introduced on the S-Series.
Introduced on the C-Series.
Original command.
•
EXEC Privilege
•
CONFIGURATION
•
LINE, INTERFACE
•
TRACE-LIST
•
PROTOCOL GVRP
119