Line
Description
Voltage
Current voltage of the sfps. If this voltage crosses voltage high
alarm/warning thresholds, the voltage high alarm/warning flag is set
to true.
Tx Bias Current
Present Tx bias current of the SFP. If this crosses bias high alarm/
warning thresholds, the tx bias high alarm/warning flag is set to true.
If it falls below the low alarm/warning thresholds, the tx bias low
alarm/warning flag is set to true.
Tx Power
Present Tx power of the SFP. If this crosses Tx power alarm/warning
thresholds, the Tx power high alarm/warning flag is set to true. If it
falls below the low alarm/warning thresholds, the Tx power low
alarm/ warning flag is set to true.
Rx Power
Present Rx power of the SFP. This value is either average Rx power
or OMA. This depends on the Rx Power measurement type displayed
above. If this crosses Rx power alarm/warning thresholds, the Rx
power high alarm/warning flag is set to true. If it falls below the low
alarm/warning thresholds, the Rx power low alarm/warning flag is
set to true.
Data Ready state
This field indicates that the transceiver has achieved power up and
Bar
data is ready. This is set to true if data is ready to be sent and set to
false if data is being transmitted.
Rx LOS state
This is the digital state of the Rx_LOS output pin. This is set to true if
the operating status is down.
Tx Fault state
This is the digital state of the Tx Fault output pin.
Rate Select state
This is the digital state of the SFP rate_select input pin.
RS state
This is the reserved digital state of the pin AS(1) per SFF-8079 and
RS(1) per SFF-8431.
Tx Disable state
If the admin status of the port is down then this flag is set to true.
Temperature High
This can be either true or false, depending on the Current voltage
Alarm Flag
value displayed above.
Voltage High Alarm
This can be either true or false, depending on the Current
Flag
Temperature value displayed above.
Tx Bias High Alarm
This can be either true or false, depending on the present TX bias
Flag
current value displayed above.
Tx Power High Alarm
This can be either true or false, depending on the Current Tx bias
Flag
power value displayed above.
Rx Power High
This can be either true or false, depending on the Current Rx power
Alarm Flag
value displayed above.
Temperature Low
This can be either true or false, depending on the Current
Alarm Flag
Temperature value displayed above.