Chapter 5
Linksys ATA Field Reference
Dial Plan
PSTN Fallback Dial Plan
Enable IP Dialing
Emergency Number
References in this section to the SPA3102 also apply to the AG310.
Note

FXS Port Polarity Configuration

Field
Idle Polarity
Caller Conn Polarity
Callee Conn Polarity
Document Version 3.2
Dial plan script for this line.
The default(*xx|[3469]11|0|00|[2-9]xxxxxx|1xxx[2-9]xxxxxxS0|xxxxxxxxxxxx.)
The dial plan syntax is expanded in the SPA3102 to allow the designation of three
parameters to be used with a specific gateway:
uid – the authentication user-id
pwd – the authentication password
nat – if this parameter is present, use NAT mapping
Each parameter is separated by a semi-colon (;).
Furthermore, it recognizes gw0, gw1, ..., gw4 as the locally configured gateways, where
gw0 represents the local PSTN gateway in the same SPA3102 unit.
Example 1:
*1xxxxxxxxxx<:@fwdnat.pulver.com:5082;uid=jsmith;pwd=xyz
Example 2:
*1xxxxxxxxxx<:@fwd.pulver.com;nat;uid=jsmith;pwd=xyz
Example 3:
[39]11<:@gw0>
<<help here>>
Enable or disable IP dialing.
The default is no.
Comma separated list of emergency number patterns. If outbound call matches one of the
pattern, SPA will disable hook flash event handling.
after the phone is on-hook. Blank signifies no emergency number. Maximum number
length is 63 characters.
The default is blank.
Description
Polarity before a call is connected: Forward or Reverse.
The default is Forward.
Polarity after an outbound call is connected: Forward or Reverse.
The default is Forward.
Polarity after an inbound call is connected: Forward or Reverse.
The default is Forward.
The condition is restored to normal
Linksys IP Phone Administrator Guide
Line Tab
5-47