Linksys RTP300 - Broadband Router With 2 Phone Ports Administration Manual

User guide
Hide thumbs Also See for RTP300 - Broadband Router With 2 Phone Ports:
Table of Contents

Advertisement

Quick Links

ADMINISTRATION
GUIDE
Linksys
ATA Administration Guide, Version 2.0

Advertisement

Table of Contents
loading

Summary of Contents for Linksys RTP300 - Broadband Router With 2 Phone Ports

  • Page 1 ADMINISTRATION GUIDE Linksys ATA Administration Guide, Version 2.0...
  • Page 2: Table Of Contents

    Technical Support Finding Information in PDF Files Finding Text in a PDF Finding Text in Multiple PDF Files Chapter 1: Introducing Linksys Analog Telephone Adapters . . . 15 Comparison of ATA Devices Linksys ATA Connectivity Requirements Linksys PAP2T Connectivity...
  • Page 3 How VoIP-To-PSTN Calls Work One-Stage Dialing Two-Stage Dialing How PSTN-To-VoIP Calls Work Terminating Gateway Calls VoIP Outbound Call Routing Configuring VoIP Failover to PSTN Sharing One VoIP Account Between the FXS and PSTN Lines Other Options Linksys ATA Administration Guide...
  • Page 4 Port Forwarding Settings section DMZ Settings section Miscellaneous Settings section System Reserved Ports Range section Appendix B: Linksys ATA Voice Field Reference ... 94 Info page Product Information section System Status section...
  • Page 5 Audio Configuration section Dial Plans section VoIP-To-PSTN Gateway Setup section VoIP Users and Passwords (HTTP Authentication) section Ring Settings section FXO (PSTN) Timer Values (sec) section PSTN Disconnect Detection section International Control (Settings) section User page Linksys ATA Administration Guide...
  • Page 6 Power Safety Information Appendix I: Software License Agreement ... . . 190 Software in Linksys Products: Software Licenses: Schedule 1 Linksys Software License Agreement Schedule 2 Linksys ATA Administration Guide...
  • Page 7 Table of Contents Schedule 3 Appendix J: Contacts ..... . . 200 Linksys ATA Administration Guide...
  • Page 8 Document Audience Preface The Linksys ATA Administration Guide is intended to help VARs and Service Providers to manage and configure the Linksys Voice System (LVS). This preface provides helpful information about this guide and other resources that are available to you. Before you begin to use this guide, refer to the following topics: •...
  • Page 9: Document Conventions

    May indicate either of the following: • A variable that should be replaced with a literal value. • The name of a page, section, or field in the user interface Indicates code samples or system output. Monospaced Font Linksys ATA Administration Guide viii...
  • Page 10 Document Purpose and Contents Document Purpose and Contents This document provides information that an administrator needs to configure the Linksys Voice System, which typically consists of a SPA9000 IP PBX, one or more SPA900 Series IP phones, and the optional SPA400 PSTN gateway and voice mail server. This guide focuses primarily on the tasks that an administrator performs to configure a SPA9000 with the SPA9000 administration web server.
  • Page 11: Related Documentation

    SPA Provisioning Guide Linksys ATA Administration Guide is part of a complete suite of documentation that is available to assist you in using and configuring Linksys devices. The following documents are of special interest to Linksys Voice System administrators. Linksys.com...
  • Page 12: Online Resources

    Network Security www.linksys.com/security Copyright and Trademarks Linksys is a registered trademark or trademark of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries. Copyright © 2008 Cisco Systems, Inc. All rights reserved. Adobe, Acrobat, and Flash are either registered...
  • Page 13: Finding Text In A Pdf

    Finding Information in PDF Files Finding Information in PDF Files Linksys documents are published as PDF files. The PDF Find/Search tool within Adobe® Reader® lets you find information quickly and easily online. You can: • Search an individual PDF. •...
  • Page 14 4. When the Results appear, click + to open a folder, and then click any link to open the file where the search terms appear. NOTE: For more information about the Find and Search functions, see the Adobe Acrobat online help. Linksys ATA Administration Guide xiii...
  • Page 15: Chapter 1: Introducing Linksys Analog Telephone Adapters

    This guide describes the administration and use of Linksys analog telephone adapters (ATAs). Linksys ATA devices are a key element in the end-to-end IP Telephony solution. A Linksys ATA device provides user access to Internet phone services through one or more standard telephone RJ-11 phone ports using standard analog telephone equipment.
  • Page 16: Comparison Of Ata Devices

    (such as on/off hook or hook flash). The Linksys ATA devices use the Session Initiation Protocol (SIP) open standard so there is little or no involvement by a “middle-man” server or media gateway controller. SIP allows interoperation with all ITSPs that support SIP.
  • Page 17 Introducing Linksys Analog Telephone Adapters Comparison of ATA Devices Figure 1 illustrates how the different Linksys ATA devices provide voice connectivity in a VoIP network. Ethernet/Wireless WRP400, RTP300, WRTP54G, and SPA2102 Fax (up to 4 SPA8000) PSTN DSL/cable modem Broadband...
  • Page 18: Linksys Ata Connectivity Requirements

    Linksys ATA device DHCP server. The address and port are translated by the Linksys ATA device using Network Address Translation (NAT) and Port Address Translation (PAT). The packet is then routed back to the internal network on the Linksys ATA device by the local router or the ISP router.
  • Page 19: Linksys Spa2102 Connectivity

    Introducing Linksys Analog Telephone Adapters Linksys ATA Connectivity Requirements Notes: • The IVR functions are accessed by connecting an analog telephone to Line 1. • For proper operation, the service provider should use an Outbound Proxy to forward all voice traffic when the PAP2T is located behind a router. If necessary, explicit port ranges can be specified for SIP and RTP.
  • Page 20: Linksys Spa3102 Connectivity

    Introducing Linksys Analog Telephone Adapters Linksys ATA Connectivity Requirements Linksys SPA3102 Connectivity As shown in the following figure, the SPA3102 has one FXS port (voice line 1). Administrative IVR (Line 1 or IP Router (with Line 2) hairpinning) or Broadband modem...
  • Page 21: Linksys Spa8000 Connectivity

    Introducing Linksys Analog Telephone Adapters Linksys ATA Connectivity Requirements Linksys SPA8000 Connectivity As shown in the following illustration, the SPA8000 consists of eight voice ports (voice lines 1-8). 8 FXS (RJ-11/RJ-21 ) ports Administrative IVR (Line 1 or IP Router (with...
  • Page 22: Ata Software Features

    Negotiation of the optimal voice codec sometimes depends on the ability of the Linksys ATA device to match a codec name with the codec used by the far-end device. The Linksys ATA device allows the network administrator to individually name the various codecs that are supported so that the Linksys ATA device can successfully negotiate the codec with the far-end equipment.
  • Page 23: Appendix A: Linksys Ata Routing Field Reference

    A relatively simple way to support proxy redundancy is to configure your DNS server with a list of SIP proxy addresses. The Linksys ATA device can be instructed to contact a SIP proxy server in a domain named in the SIP message. The Linksys ATA device consults the DNS server to get a list of hosts in the given domain that provides SIP services.
  • Page 24 Echo Cancellation Impedance mismatch between the telephone and the IP Telephony gateway phone port can lead to near-end echo. The Linksys ATA device has a near- end echo canceller that compensates for impedance match. The Linksys ATA device also implements an echo suppressor with comfort noise generator (CNG) so that any residual echo is not noticeable.
  • Page 25 Feature Description Signaling Hook Flash The Linksys ATA device can signal hook flash events to the remote party on a Event connected call. This feature can be used to provide advanced mid-call services with third-party-call-control. Depending on the features that the...
  • Page 26 ”Linksys ATA Voice Field Reference, ” on page 94 SIP Over TLS Linksys SPA2102 and SPA3102 devices allow the use of SIP over Transport Layer Security (TLS). SIP over TLS is designed to eliminate the possibility of malicious activity by encrypting the SIP messages of the service provider and the end user.
  • Page 27 DHCP server periodically renews the device lease on the IP address. Therefore, if a Linksys ATA device loses its IP address for any reason, or if some other device on the network is assigned its IP address, the communication between the SIP proxy and the device is either severed or degraded.
  • Page 28: Chapter 2: Basic Administration And Configuration Of Your Linksys Ata Device

    ”Provisioning Your Linksys ATA Device” section on page 35 • Basic Services and Equipment Required To configure your Linksys ATA devices, you need the following services and equipment: • An integrated access device or modem for broadband access to the Internet •...
  • Page 29: Downloading Firmware" Section

    Basic Administration and Configuration of Your Linksys ATA Downloading Firmware Downloading Firmware Always download and install the latest firmware for your Linksys ATA device before doing any configurations. 1. Direct your browser to the following URL: http://www.linksys.com Search 2. In the box near the top right corner of the page, type the model number of your Linksys ATA device.
  • Page 30: Basic Installation And Configuration" Section

    Click OK to close the confirmation message. g. To verify the upgrade, point the web browser to the IP address of the Linksys ATA device. Check the Router > Status page. The Software Version field should show the firmware version that you installed.
  • Page 31: Setting Up Your Linksys Ata Device" Section

    Setting up Your Linksys ATA Device Setting up Your Linksys ATA Device After installation and basic configuration of your Linksys ATA device, you will use the administration web server to finish your configuration. Linksys ATA devices support two levels of administration privileges: Administrator and User.
  • Page 32: Connecting To The Administration Web Server

    Using the Administration Web Server Connecting to the Administration Web Server To access the Linksys ATA administration web server, perform the following steps. 1. Start Internet Explorer on a computer that is connected to the same network as the ATA device.
  • Page 33: Registering To The Service Provider

    WAN Connection Type, Current IP, Current Netmask, Current Gateway, and Primary DNS. Registering to the Service Provider To use VoIP phone service, you must configure your Linksys ATA device to the Service Provider. 1. Start Internet Explorer, connect to the administration web server, and choose Admin access with Advanced settings.
  • Page 34: Upgrading, Rebooting, And Resyncing Your Linksys Ata Device" Section

    Basic Administration and Configuration of Your Linksys ATA Upgrading, Rebooting, and Resyncing Your Linksys ATA Device • Use an external phone to place an inbound call to the telephone number that was assigned by your ITSP. Assuming that you have left the default settings in place, the phone should ring and you can pick up the phone to get two-way audio.
  • Page 35: Provisioning Your Linksys Ata Device" Section

    Basic Administration and Configuration of Your Linksys ATA Provisioning Your Linksys ATA Device If no port specified, the default port of the protocol is used. (69 for TFTP or 80 for HTTP) The firmware-pathname is typically the file name of the binary located in a directory on the TFTP or HTTP server.
  • Page 36: Provisioning Capabilities

    Linksys Profile Compiler (SPC) tool compiles a plain-text file containing parameter-value pairs into a properly formatted and encrypted .cfg file. The SPC tool is available from Linksys for the Win32 environment and Linux-i386-elf environment. Requests for SPC tools compiled on other platforms are evaluated on a case-by-case basis.
  • Page 37 Basic Administration and Configuration of Your Linksys ATA Provisioning Your Linksys ATA Device The names of parameters in XML profiles can generally be inferred from the ATA configuration Web pages, by substituting underscores (_) for spaces and other control characters. Further, to distinguish between Lines 1, 2, 3, and 4, corresponding parameter names are augmented by the strings _1_, _2_, _3_, and _4_.
  • Page 38: Chapter 3: Configuring Your System For Itsp Interoperability

    If the ITSP network does not provide a Session Border Controller functionality, you can achieve NAT mapping by using a router that has a SIP ALG (Application Layer Gateway). The Linksys WRV200 router is recommended for this purpose, although any router with a SIP-ALG can be used.
  • Page 39: Configuring Nat Mapping With A Static Ip Address

    4. Click Voice tab > Line N, where N represents the line interface number. 5. Scroll down to the NAT Settings section. • NAT Mapping Enable: Choose YES. • NAT Keep Alive Enable: Choose YES (optional). Voice tab > Line N > NAT Settings Linksys ATA Administration Guide...
  • Page 40: Configuring Nat Mapping With Stun

    Insert VIA received: yes • Insert VIA rport: yes • Substitute VIA Addr: yes • Send Resp To Src Port: yes • STUN Enable: Choose yes. • STUN Server: Enter the IP address for your STUN server. Linksys ATA Administration Guide...
  • Page 41: Determining Whether The Router Uses Symmetric Or Asymmetric Nat

    1. Make sure you do not have firewall running on your PC that could block the syslog port (port 514 by default). 2. Connect to the administration web server, and choose Admin access with Advanced settings. Linksys ATA Administration Guide...
  • Page 42: Firewalls And Sip

    Make sure that the following ports are not blocked: – SIP ports—UDP port 5060 through 5063, which are used for the ITSP line interfaces – RTP ports—16384 to 16482 • Also disable SPI (Stateful Packet Inspection) if this function exists on your firewall. Linksys ATA Administration Guide...
  • Page 43: Configuring Sip Timer Values

    To view the default settings or to make changes, open the Voice > SIP page, and scroll down to the SIP Timer Values section. For field descriptions, see ”SIP Timer Values (sec) section, ” on page 103 of Appendix Linksys ATA Administration Guide...
  • Page 44: Chapter 4: Configuring Voice Services

    • Supported Codecs The following list shows the current supported codecs for each Linksys ATA device. If you need to change the G711u codec which is configured by default, set your preferred codecs in the FXS Line tab(s); Audio Configuration. You may set your first, second, and third preferred codec. See ”Linksys ATA Routing Field Reference,”...
  • Page 45: Using A Fax Machine (Spa2102, Spa3102 Or Spa8000)

    (1/2, 3/4, 5/6, and 7/8) for a maximum of four connections. To optimize fax completion rates, complete the following steps: 1. Upgrade the Linksys ATA firmware to the latest version 2. Ensure that you have enough bandwidth for uplink and downlink.
  • Page 46: Fax Troubleshooting

    If have problems sending or receiving faxes, complete the following steps: 1. Verify that your fax machine is set to a speed between 7200 and 14400. 2. Send a test fax in a controlled environment between two Linksys ATAs. 3. Determine the success rate.
  • Page 47: Managing Caller Id Service

    Managing Caller ID Service 8. Contact technical support. If you are an end user of Linksys VoIP products, contact the reseller or Internet telephony service provider (ITSP) that supplied the equipment. If you are an authorized Linksys Voice System partner, contact Linksys technical support.
  • Page 48: Silence Suppression And Comfort Noise Generation

    Noise Generation is not used, the caller may think the call has been disconnected because of the “dead silence” periods created by the VAD and Silence Suppression feature. ”Linksys ATA Routing Field Silence suppression is configured in the Line and PSTN Line tabs. See Reference,”...
  • Page 49: Configuring Dial Plans

    0 1 2 3 4 5 6 7 8 9 0 * # Enter any of these characters to represent a key that the user must press on the phone keypad. Enter to represent any character on the phone keypad. Linksys ATA Administration Guide...
  • Page 50: Digit Sequences

    Enter an asterisk to allow the user to enter a 2-digit star code. Enter to reduce the short inter-digit timer to 0 seconds, or S0 or L0 enter L0 to reduce the long inter-digit timer to 0 seconds. Linksys ATA Administration Guide...
  • Page 51: Digit Sequence Examples

    | 9, 1 900 xxxxxxx ! | 9, 011xxxxxx. | 0 | [49]11 ) After the user presses 9, an external dial tone sounds. The user can 9, 1 [2-9] xxxxxxxxx enter any 11-digit number that starts with 1 and is followed by a digit 2 through 9. Linksys ATA Administration Guide...
  • Page 52: Acceptance And Transmission The Dialed Digits

    The dialed digits exactly match one the number is accepted and is transmitted sequence in the dial plan. according to the dial plan. • If the sequence is blocked by the dial plan, the number is rejected. Linksys ATA Administration Guide...
  • Page 53: Dial Plan Timer (Off-Hook Timer)

    After taking a phone off hook, a user has 9 seconds to begin dialing. If no digits are pressed within 9 seconds, the user hears a reorder (fast busy) tone. By setting a longer timer, you allow more time for users to enter the digits. Linksys ATA Administration Guide...
  • Page 54: Interdigit Long Timer (Incomplete Entry Timer)

    This dial plan allows the user to pause for up to 15 seconds between digits before the L:15, Interdigit Long Timer expires. This setting is especially helpful to users such as sales people, who are reading the numbers from business cards and other printed materials while dialing. Linksys ATA Administration Guide...
  • Page 55: Interdigit Short Timer (Complete Entry Timer)

    1. Connect to the administration web server, and choose Admin access with Advanced settings. 2. Click Voice tab > Line N, where N represents the line interface number. 3. Scroll down to the Dial Plan section. Linksys ATA Administration Guide...
  • Page 56 3. Scroll down to the Control Timer Values section. 4. Enter the desired values in the Interdigit Long Timer field and the Interdigit Short Timer field. Refer to the definitions at the beginning of this section. Voice > Regional: Control Timer Values Linksys ATA Administration Guide...
  • Page 57: Secure Call Implementation

    The ATA device will not switch to secure mode if the CID of the called party from its Mini- Certificate does not agree with the user-id used in making the outbound call. The ATA device performs this check after receiving the Mini-Certificate of the called party Linksys ATA Administration Guide...
  • Page 58: Secure Call Details

    The MC is signed with a 1024-bit private key of the service provider, which acts as the CA of the MC. The 1024-bit public key of the CA signing the MC must also be provisioned for each subscriber. Linksys ATA Administration Guide...
  • Page 59: Generating A Mini Certificate

    SIP INFO messages to pass through with the message body unmodified. Generating a Mini Certificate Linksys provides a Mini Certificate Generator for the generation of mini certificates and private keys. • Partners in North America can find the Mini Certificate Generator on the SPA Utilities page at the Linksys Partner Connection (LPC) at Linksys.com.
  • Page 60 The tool generates the Mini Certificate and SRTP Private Key parameters that can be provisioned. For example: gen_mc ca_key “Joe Smith” 14085551234 “00:00:00 1/1/34” Produces the following Mini Certificate and SRTP Private Key: <Mini Certificate> Sm9lIFNtaXRoAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAxNDA4NTU1MTIzNAAAAAAAMDAwMDAwMDEwMTM00O vJakde2vVMF3Rw4pPXL7lAgIagMpbLSAG2+++YlSqt198Cp9rP/ xMGFfoPmDKGx6JFtkQ5sxLcuwgxpxpxkeXvpZKlYlpsb28L4Rhg5qZA+Gqj1hDFCmG6dffZ9SJhxES767G 0JIS+N8lQBLr0AuemotknSjjjOy8c+1lTCd2t44Mh0vmwNg4fDck2YdmTMBR516xJt4/uQ/ LJQlni2kwqlm7scDvll5k232EvvvVtCK0AYa4eWd6fQOpiESCO9CC9aYU1X5lJuU+EBZmi3AmcqE9U1LxE OGwopaGyGOh3VyhKgi6JaVtQZt87PiJINKW8XQj3B9Qqe3VgYxWCQNa335YCnDsenASeBxuMIEaBCYd1l1 fVEodJZOGwXwfAde0MhcbD0kj7LVlzcsTyk2TZYTccnZ75TuTjj13qvYs= <SRTP Private Key> b/DWc96X4YQraCnYzl5en1CIUhVQQqrvcr6Qd/8R52IEvJjOw/ e+Klm4XiiFEPaKmU8UbooxKG36SEdKusp0AQ== Linksys ATA Administration Guide...
  • Page 61: Sip Trunking And Hunt Groups On The Spa8000

    • ”Configuring a Trunk Group, ” on page 67 • ”Additional Notes About Trunk Groups, ” on page 69 • ”Setting the Hunt Policy, ” on page 69 • ”Trunk Group Management, ” on page 68 Linksys ATA Administration Guide...
  • Page 62: About Sip Trunking

    • Outbound calling: When a PBX phone makes a call, the PBX selects one of the available trunk lines. The trunk line assumes the Caller ID of the trunk group. Linksys ATA Administration Guide...
  • Page 63 RTP packets directly with the ITSP equipment. NOTE: Although the figure shows only one ITSP account, in fact each standalone line and each Trunk Group can be configured with a different ITSP (with some limitations applied). Linksys ATA Administration Guide...
  • Page 64: Setting The Trunk Group Call Capacity

    The Trunk UA in turn replies 200 OK to the ITSP and relay the Line SDP in the 200 OK message also. If all goes well, the Line UA and the ITSP equipment start exchanging RTP packets afterwards. Linksys ATA Administration Guide...
  • Page 65: Contact List For A Trunk Group

    : The maximum duration of the hunt, either in seconds or cycles. When this limit is reached, the call is rejected or is forwarded to the specified call forward number (see below). – If is greater than , it represents the total time in seconds to hunt. interval Linksys ATA Administration Guide...
  • Page 66: Outgoing Call Routing For A Trunk Group

    ITSP if there is available capacity on the trunk. If there is no call capacity left on the trunk, the internal Proxy will reject the INVITE from the Line UA, which in turn terminates the call and plays reorder tone out to the FXS port. Linksys ATA Administration Guide...
  • Page 67: Configuring A Trunk Group

    In the Trunk Group field, near the top of the line configuration page, choose a trunk number or choose none for a standalone line (the default setting). c. Repeat this step for each line that you want to add to a trunk group. Voice > Ln > Trunk Group field Linksys ATA Administration Guide...
  • Page 68: Trunk Group Management

    This page shows a snapshot of the trunk activity. You can refresh the data at any time by clicking the Refresh button on the web browser toolbar. The page shows the following information: • External: The called number • Station: The SPA8000 line that is in use for this call Linksys ATA Administration Guide...
  • Page 69: Additional Notes About Trunk Groups

    Via the PBX, the phone user can trigger/control supplementary service and settings by signaling to the line port or configuring the line parameters. For more information, refer to the Appendix B, "Linksys ATA Voice Field Reference." Linksys ATA Administration Guide...
  • Page 70: Chapter 5: Configuring Music On Hold

    6. Enter the following value in the MOH Server field: imusic 7. Click Submit All Changes. 8. To verify, place a test call to the extension. When the call is answered and put on hold, the caller should hear the default music file (Romance de Amor). Linksys ATA Administration Guide...
  • Page 71: Changing The Music File For The Internal Music Source

    The Streaming Audio Server (SAS) feature lets you attach an audio source to an FXS port and use it as a streaming audio source device. If the unit has multiple FXS ports, either or both of the associated lines can be configured as an SAS server. Linksys ATA Administration Guide...
  • Page 72: Configuring The Streaming Audio Server

    Configuring a Streaming Audio Server Use a media signal adapter to connect an Ethernet cable from a media source to the FXS port. The following is a URL for a device that has been tested with Linksys ATA devices: http://www.neogadgets.com/cart/cart.php?target=product&product_id=17&substring =music+coupler After you complete the required configuration, the FXS port is ready to stream audio.
  • Page 73: Using The Ivr With An Sas Line

    IVR may be used. But if the ATA device boots up and finds that the SAS line is off- hook, it removes battery from the line because no audio session is in progress. Linksys ATA Administration Guide...
  • Page 74: Chapter 6: Configuring The Pstn (Fxo) Gateway

    • VoIP caller—One who calls the Linksys ATA device via VoIP to obtain PSTN service • VoIP user—VoIP caller that has a user account (user-id and password) on the Linksys ATA device • PSTN caller—One who calls the Linksys ATA device from the PSTN to obtain VoIP service Line 1 can be configured with a regular VoIP account and can be used in the same way as the Line 1 of any Linksys ATA device.
  • Page 75: How Voip-To-Pstn Calls Work

    If the FXO port is currently in use (off-hook) or the PSTN line is being used by another extension, the Linksys ATA device replies to the INVITE with a 503 response. Otherwise, it compares the <Dialed-Number> with the User ID parameter of the PSTN Line. If they are the same, the Linksys ”Two-Stage Dialing” section...
  • Page 76: Two-Stage Dialing

    10 seconds (not configurable). Up to eight VoIP caller PIN numbers can be configured on the Linksys ATA device. A dial plan can be selected for each PIN number. If the caller enters a wrong PIN or the Linksys ATA device times out waiting for more PIN digits, the Linksys ATA device tears down the call immediately with a BYE request.
  • Page 77: How Pstn-To-Voip Calls Work

    Linksys ATA device. If the given PIN does not match any of the PSTN PIN values, the Linksys ATA device plays the reorder tone to the FXO port for up to 10 seconds, and then takes the FXO port on-hook. If the given PIN matches one of PSTN PIN values, the Linksys ATA device plays dial tone to the FXO port and is ready to accept digits for the target VoIP number from the PSTN caller.
  • Page 78: Voip Outbound Call Routing

    You can override this behavior by IP dialing, through which the calls can be routed to any IP address entered by the user. The Linksys ATA device allows flexible call routing with four sets of gateway parameters and configurable dial plans. The following table lists VoIP outbound call routing parameters.
  • Page 79: Configuring Voip Failover To Pstn

    FXO port. However, if the PSTN line is in use when the power is applied to the Linksys ATA device, the relay is not flipped until the PSTN line is released. This is done so that the Linksys ATA device does not interrupt any call in progress on the PSTN line.
  • Page 80: Sharing One Voip Account Between The Fxs And Pstn Lines

    800 area code to 18005558355 (This is the number for Tell Me). When this syntax is used, authentication is not used and the target PSTN number is automatically dialed by the Linksys ATA device after the caller is forwarded to gw0. Linksys ATA Administration Guide...
  • Page 81: Other Options

    Configuring the PSTN (FXO) Gateway Other Options Other Options This section describes other options provided by the Linksys ATA device. It includes the following topics: ”PSTN Call to Ring Line 1” section on page 81 • ”Symmetric RTP” section on page 81 •...
  • Page 82 PSTN dial plan is used. Note than the dial plan choice cannot be 0 for a PSTN caller. NOTE: A PSTN Access List in terms of Caller ID (ANI) patterns can be configured into the Linksys ATA device to automatically grant access to the PSTN caller without entering the PIN. In this case, the default PSTN dial plan is also used.
  • Page 83 If the PSTN Line is busy (off-hook, ringing, or PSTN line not connected) when the VoIP caller calls, the Linksys ATA device replies with 503. If the PIN number is invalid or entered after the VoIP call leg is connected, the Linksys ATA device plays the reorder tone to the VoIP caller and eventually ends the call when the reorder tone times out.
  • Page 84 A comma-separated list of IP address templates, For example: such that callers with a source IP address matching 192.168.*.*, any of the templates are accepted for PSTN 66.43.12.1??. gateway service without further authentication. The default is blank. Linksys ATA Administration Guide...
  • Page 85: Call Forwarding To Pstn Gateway

    In this scenario, the forward destination is set to <target-number>@gw0>. This is the same as in the previous examples, except that the Linksys ATA device automatically dials the given target number on the PSTN line right after it answers the VoIP call leg. This is a special case of one- stage dialing where the target number is specified in the configuration.
  • Page 86: Product Information Section

    SPA3102, and SPA8000 routers. To configure router settings for the PAP2T, AG310, RTP300, WRP400, WAG54GP2, and WRTP54G, see the Linksys user guide for the router. After you click the Router tab on the SPA2102, SPA3102, or the Network tab on the SPA8000, you can choose the following pages: •...
  • Page 87: System Status Section

    You can use the WAN Setup page to enter the WAN connection settings. This page includes the following sections: • ”Internet Connection Settings section, ” on page 88 • ”Static IP Settings section, ” on page 88 • ”PPPoE Settings section, ” on page 88 Linksys ATA Administration Guide...
  • Page 88 The password assigned by the ISP for connecting on a Point-to-Point Protocol over Ethernet (PPPoE) link. PPPoE Service Name The service name assigned by the ISP for connecting on a Point-to-Point Protocol over Ethernet (PPPoE) link. Linksys ATA Administration Guide...
  • Page 89 MAC address you have currently registered with your ISP to the router with the MAC Address Clone feature. Enable MAC Clone Service To use MAC Address cloning, select Yes. Default is No. Cloned MAC Address Use when your ISP requires a certain MAC address. It’s usually the address for your PC. Linksys ATA Administration Guide...
  • Page 90 You can use the LAN Setup page to enter your LAN settings. This page includes the following sections: • ”Networking Service section, ” on page 91 • ”LAN Networking Settings section, ” on page 91 • ”Static DHCP Lease Settings section, ” on page 91 Linksys ATA Administration Guide...
  • Page 91 Router tab > LAN Setup page > LAN Networking Settings section Use these network settings when using NAT. LAN IP Address IP address of the Linksys ATA device on the LAN side. LAN Subnet Mask IP address for subnet mask. Enable DHCP Server Options are Yes or No for the DHCP Server to provide an IP address.
  • Page 92 IP address assigned to it because its address may change when using the DHCP function. To expose one PC, select Yes. The default is No. DMZ Host IP Address Specify the host computer’s IP address. Linksys ATA Administration Guide...
  • Page 93 That is, if there is a conflict — if port forwarding is set on the same port — then the port forwarding is cancelled. Default is 50000. Num of Ports Reserved Total number of ports reserved. Options are: 256, 512, and 1024. Linksys ATA Administration Guide...
  • Page 94 This chapter describes the settings that you can configure under the Voice tab in the administration web server pages. NOTE: For information about the Voice > Provisioning tab, see the Linksys SPA Provisioning Guide. After you click the Voice tab, you can choose the following pages: •...
  • Page 95: Line Status Section

    Hook state of the FXO port. Options are either On or Off. Registration State Indicates if the line has registered with the SIP proxy. Last Registration At Last date and time the line was registered. Next Registration In Number of seconds before the next registration renewal. Linksys ATA Administration Guide...
  • Page 96 Number of packets received. Recv Call 1 and 2 Bytes Sent Number of bytes sent. Call 1 and 2 Bytes Recv Number of bytes received. Call 1 and 2 Decode Number of milliseconds for decoder latency. Latency Linksys ATA Administration Guide...
  • Page 97: System Information Section (Pap2T)

    The PSTN number dialed by the SPA (logged only if a non-trivial dial plan is Number used). Last VoIP Caller The last VoIP caller to the FXO Line. Last PSTN Caller Name and number of the last PSTN caller. Linksys ATA Administration Guide...
  • Page 98 VoIP Peer Number Phone number of the party at the VoIP call leg. PSTN Peer Number Phone number of the party at the PSTN call leg. VoIP Call Encoder Audio encoder being used for the VoIP call leg. Linksys ATA Administration Guide...
  • Page 99: Trunk Status Section (Spa8000)

    ”System Configuration section” section on page 100 • ”Internet Connection Type section (PAP2T)” section on page 100 • ”Optional Network Configuration section (PAP2T)” section on page 100 • ”Miscellaneous Settings section (not used with PAP2T)” section on page 101 Linksys ATA Administration Guide...
  • Page 100: System Configuration Section

    The network domain of the ATA device. Primary DNS DNS server used by ATA device in addition to DHCP supplied DNS servers if DHCP is enabled; when DHCP is disabled, this is the primary DNS server. The default is 0.0.0.0. Linksys ATA Administration Guide...
  • Page 101: Miscellaneous Settings Section (Not Used With Pap2T)

    Determines the level of debug information that is generated. Select 0, 1, 2, or 3 from the drop-down menu. The higher the debug level, the more debug information is generated. The default is 0, which indicates that no debug information is generated. Linksys ATA Administration Guide...
  • Page 102: Sip Page

    MIME Type used in a SIP INFO message to signal a DTMF event. The default is application/dtmf-relay. Hook Flash MIME Type MIME Type used in a SIP INFO message to signal a hook flash event. The default is application/hook-flash. Linksys ATA Administration Guide...
  • Page 103: Sip Timer Values (Sec) Section

    SIP Timer B INVITE time-out value, which can range from 0 to 64 seconds. The default is 32. SIP Timer F Non-INVITE time-out value, which can range from 0 to 64 seconds. The default is 32. Linksys ATA Administration Guide...
  • Page 104 Register Retry Intvl seconds after a failure. If this feature is enabled, Reg Retry Random Delay is added on top of the exponential back-off adjusted delay value. The default value is 0, which disables the exponential back-off feature. Linksys ATA Administration Guide...
  • Page 105: Response Status Code Handling Section

    Number of successive ICMP errors allowed when transmitting RTP packets to the peer before the ATA device terminates the call. If value is set to 0, the ATA device ignores the limit on ICMP errors. The default is 0. Linksys ATA Administration Guide...
  • Page 106: Sdp Payload Types Section

    NAME, and TOOL identifiers. The CNAME is set to <User ID>@<Proxy>, NAME is set to <Display Name> (or Anonymous if user blocks caller ID), and TOOL is set to the Vendor/Hardware-platform-software-version (such as Linksys/ATA device-1.0.31(b)). The NTP timestamp used in the SR is a snapshot of the ATA device’s local time, not the time reported by an NTP server.
  • Page 107: Nat Support Parameters Section

    Insert VIA received Inserts the received parameter into the VIA header of SIP responses if the received-from IP and VIA sent-by IP values differ. Select yes or no from the drop-down menu. The default is no. Linksys ATA Administration Guide...
  • Page 108 RTP port number in all outgoing SIP messages is substituted for the corresponding port value in the external RTP port range. The default is 0. NAT Keep Alive Intvl Interval between NAT-mapping keep alive messages. The default is 15. Linksys ATA Administration Guide...
  • Page 109: Trunking Parameters Section (Spa8000)

    An incoming call is directed to a specified trunk line only if the call state is onhook. • any state: An incoming call is directed to any specified trunk line without regard to the call state. Linksys ATA Administration Guide...
  • Page 110: Regional

    Played when an outbound call has failed or after the far end hangs up during an established call. Reorder Tone is played automatically when Dial Tone or any of its alternatives times out. The default is 480@-19,620@-19;10(.25/.25/1+2). Linksys ATA Administration Guide...
  • Page 111 Played when a call has been successfully switched to secure mode. It should Tone be played only for a short while (less than 30 seconds) and at a reduced level (less than -19 dBm) so it does not interfere with the conversation. The default is 397@-19,507@-19;15(0/2/0,.2/.1/1,.1/2.1/2). Linksys ATA Administration Guide...
  • Page 112: Distinctive Ring Patterns Section

    The default is 60(.4/.2,.4/.2,.4/4). Ring8 Cadence Cadence script for distinctive ring 8. The default is 60(0.25/9.75). Ring9 Cadence Cadence script for distinctive ring 9. This field is for the SPA2102 and SPA8000 only. The default is 60(.4/.2,.4/2). Linksys ATA Administration Guide...
  • Page 113: Distinctive Call Waiting Tone Patterns Section

    Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 4 for the inbound call. The default is Bellcore-r4. Ring5 Name Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 5 for the inbound call. The default is Bellcore-r5. Linksys ATA Administration Guide...
  • Page 114: Ring And Call Waiting Tone Spec Section

    It does not apply to outbound calls. Range: 0–255 seconds. The default is 0. Reorder Delay Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf = never plays. Range: 0–255 seconds. The default is 5. Linksys ATA Administration Guide...
  • Page 115 After that, tip-to-ring voltage is restored and dial tone applies if the attached equipment is still off-hook. CPC is disabled if this value is set to 0. Range: 0 to 1.000 second. Resolution is 0.001 second. The default is 0 (CPC disabled). Linksys ATA Administration Guide...
  • Page 116: Vertical Service Activation Codes Section

    Cancels call forwarding of the last inbound or outbound calls. The default is *83. Block Last Act Code Blocks the last inbound call. The default is *60. Block Last Deact Code Cancels blocking of the last inbound call. The default is *80. Linksys ATA Administration Guide...
  • Page 117 Dist Ring Act Code Enables the distinctive ringing feature. The default is *26 Dist Ring Deact Code Disables the distinctive ringing feature. The default is *46. Speed Dial Act Code Assigns a speed dial number. The default is *74. Linksys ATA Administration Guide...
  • Page 118 The *codes should not conflict with any of the other vertical service codes internally processed by the ATA device. You can empty the corresponding *code that you do not want to ATA device to process. Linksys ATA Administration Guide...
  • Page 119: Vertical Service Announcement Codes Section (Spa2102, Spa8000)

    *73. Voice tab > Regional page > Vertical Service Announcement Codes section (SPA2102, SPA8000) Field Description Service Annc Base Base number for service announcements. Number Service Annc Extension Extension codes for service announcements. Codes Linksys ATA Administration Guide...
  • Page 120: Outbound Call Codec Selection Codes Section

    Prefer G729a Code Makes this codec the preferred codec for the associated call. The default is *01729. Force G729a Code Makes this codec the only codec that can be used for the associated call. The default is *02729. Linksys ATA Administration Guide...
  • Page 121: Miscellaneous Section

    The default Daylight Saving Time Rule is start=4/1/7;end=10/-1/7;save=1. Daylight Saving Time Daylight Saving Time can be turned on or off. This option affects the time Enable stamp on CallerID and affects all the lines and extensions of the phone. Default is Yes (on). Linksys ATA Administration Guide...
  • Page 122 The default is bell 202. This field is not found in the PAP2T. FXS Port Power Limit The choices are from 1 to 8. This field is only found in the PAP2T. The default is 3. Linksys ATA Administration Guide...
  • Page 123: Line

    The SPA2102 provides one User tab for each Line tab (User 1 and User 2), where many of the line-specific configuration parameters are contained. The SPA8000 does not provide User tabs, but consolidates all the line-specific parameters on the Line tab. Linksys ATA Administration Guide...
  • Page 124: Line Enable Section

    Special case: If the value is $IP, then the SAS line’s own IP address is used in the c = line and a=sendrecv. In that case the SAS client will stream RTP packets to the SAS line. The default value is empty. Linksys ATA Administration Guide...
  • Page 125: Nat Settings Section

    The default is high. Jitter Buffer Adjustment Controls how the jitter buffer should be adjusted. Select the appropriate setting: up and down, up only, down only, or disable. The default is up and down. Linksys ATA Administration Guide...
  • Page 126: Sip Settings Section

    This feature was requested by Bell Canada (Nortel) to limit the registration of SIP accounts. The default is yes. Linksys ATA Administration Guide...
  • Page 127 If this feature is enabled, the IP telephony ignores further 180 SIP responses after receiving the first 183 SIP response for an outbound INVITE. To enable this feature, select yes. Otherwise, select no. The default is no. Linksys ATA Administration Guide...
  • Page 128: Call Feature Settings Section

    SIP Outbound Proxy Server where all outbound requests are sent as the first hop. Use Outbound Proxy Enablse the use of an Outbound Proxy. If set to no, the Outbound Proxy and Use OB Proxy in Dialog parameters are ignored. The default is no. Linksys ATA Administration Guide...
  • Page 129 The default is Normal. Voice Mail Server Enter the URL or IP address of the server. Mailbox Subscribe Expiry time to the voice mail server. The time to send another subscribe Expires message to the voice mail server. Linksys ATA Administration Guide...
  • Page 130: Subscriber Information Section

    The default is yes. Block CID Serv Enable Block Caller ID Service. The default is yes. Block ANC Serv Enable Block Anonymous Calls Service The default is yes. Dist Ring Serv Enable Distinctive Ringing Service The default is yes. Linksys ATA Administration Guide...
  • Page 131 Enable MWI Service. MWI is available only if a Voice Mail Service is set-up in the deployment. The default is yes. VMWI Serv Enable VMWI Service (FSK). The default is yes. Speed Dial Serv Enable Speed Dial Service. The default is yes. Linksys ATA Administration Guide...
  • Page 132: Audio Configuration Section

    This value is the authentication user-id to be used by the SPA to authenticate itself to Gateway 1. The default is blank. GW1/2/3/4 Password This value is the password to be used by the SPA to authenticate itself to Gateway 1. The default is blank. Linksys ATA Administration Guide...
  • Page 133: Voip Fallback To Pstn Section (Spa3102/Ag310)

    Dial Plan Entry Functionality Allow arbitrary 2 digit star code [3469]11 Allow x11 sequences Operator Int’l Operator [2-9]xxxxxx US local number 1xxx[2-9]xxxxxx US 1 + 10-digit long distance number xxxxxxxxxxxx. Everything else (Int’l long distance, FWD, ...) Linksys ATA Administration Guide...
  • Page 134 SPA will disable hook flash event handling. The condition is restored to normal after the phone is on- hook. Blank signifies no emergency number. Maximum number length is 63 characters. The default is blank. Linksys ATA Administration Guide...
  • Page 135: Fxs Port Polarity Configuration Section

    ”Proxy and Registration section” section on page 145 Voice tab > Trunk Group page > Line Enable section Field Description Line Enable To enable this line for service, select yes. Otherwise, select no. The default is yes. Linksys ATA Administration Guide...
  • Page 136: Network Settings Section

    This feature was requested by Bell Canada (Nortel) to limit the registration of SIP accounts. The default is yes. Linksys ATA Administration Guide...
  • Page 137 The default is 0. Refer-To Target To contact the refer-to target, select yes. Otherwise, select no. Contact The default is no. Auth INVITE When enabled, authorization is required for initial incoming INVITE requests from the SIP proxy. Linksys ATA Administration Guide...
  • Page 138: Subscriber Information Section

    (hunt=ra). If there is no answer within 12 seconds (12), the Trunk SUA chooses another line at random. If there is no answer after 1 round (1), the call is forwarded to forwarded to the specified number (cfwd=14089993326). Linksys ATA Administration Guide...
  • Page 139: Dial Plan Section

    The default is $NOTIFY. NAT Keep Alive Dest Destination that should receive NAT keep alive messages. If the value is $PROXY, the messages are sent to the current proxy server or outbound proxy server. The default is $PROXY. Linksys ATA Administration Guide...
  • Page 140: Proxy And Registration Section

    (Using multiple DNS A record per server name does not allow the notion of priority and so all hosts will be considered at the same priority and the PAP2T will not attempt to fall back after a fail over). The default is 3600 Linksys ATA Administration Guide...
  • Page 141: Pstn Line Page (Ag310 And Spa3102)

    ”VoIP Users and Passwords (HTTP Authentication) section” section on page 150 • ”FXO (PSTN) Timer Values (sec) section” section on page 151 • ”PSTN Disconnect Detection section” section on page 153 • ”International Control (Settings) section” section on page 155 Linksys ATA Administration Guide...
  • Page 142: Line Enable Section

    CoS value for SIP messages. The default is 3. RTP ToS/DiffServ Value ToS/DiffServ field value in UDP IP packets carrying RTP data. The default is 0xb8. RTP CoS Value [0-7] CoS value for RTP data. The default is 6. Linksys ATA Administration Guide...
  • Page 143: Sip Settings Section

    SIP request. The GUID is generated the first time the unit boots up and stays with the unit through rebooting and even factory reset. This feature was requested by Bell Canada (Nortel) to limit the registration of SIP accounts. The default is yes. Linksys ATA Administration Guide...
  • Page 144 If this feature is enabled, the IP telephony ignores further 180 SIP responses after receiving the first 183 SIP response for an outbound INVITE. To enable this feature, select yes. Otherwise, select no. The default is no. Linksys ATA Administration Guide...
  • Page 145: Proxy And Registration Section

    The default is no. DNS SRV Auto Prefix If enabled, the PAP2T will automatically prepend the Proxy or Outbound Proxy name with _sip._udp when performing a DNS SRV lookup on that name. The default is no. Linksys ATA Administration Guide...
  • Page 146: Subscriber Information Section

    G711a and G711u. On the other hand, two G.723.1/G.726 resources are available per device. Therefore it is important to disable the use of G.729a in order to guarantee the support of two simultaneous G.723/G.726 codec. Linksys ATA Administration Guide...
  • Page 147 G726-40 Enable To enable the use of the G726 codec at 40 kbps, select yes. Otherwise, select The default is yes. FAX Passthru Codec Select the codec for fax passthrough, G711u or G711a. The default is G711u. Linksys ATA Administration Guide...
  • Page 148 SPA3102 sends RTP packets to the source address and port of the last received valid inbound RTP packet. If disabled (or before the first RTP packet arrives) the SPA3102 sends RTP to the destination as indicated in the inbound SDP. The default is yes. Linksys ATA Administration Guide...
  • Page 149: Dial Plans Section

    Default VoIP Caller DP Index of the dial plan in the dial plan pool to be used when the VoIP Caller is not authenticated. Choose from {none, 1, 2, 3, 4, 5, 6, 7, 8}. The default is 1. Linksys ATA Administration Guide...
  • Page 150: Voip Users And Passwords (Http Authentication) Section

    The password to be used with VoIP User 1. The user assumes the identity of 8 Password VoIP User 1 must therefore compute the credentials using this password, or the INVITE will be challenged with a 401 response The default is blank. Linksys ATA Administration Guide...
  • Page 151: Ring Settings Section

    PIN digits from a VoIP caller. The range is 0-255. The default is 10. PSTN PIN Digit Timeout to wait for the 1 or subsequent PIN digits from a PSTN caller. The Timeout range is 0-255. The default is 10. Linksys ATA Administration Guide...
  • Page 152 PSTN Hook Flash Len The length of the hook flash in seconds. During a PSTN-to-VoIP gateway call, the Linksys ATA device processes the out-of-band hook flash signal sent from the VoIP peer through a hook-flash (momentary on-hook signal) on the FXO port. This allows the VoIP peer to initiate a three-way conference call and subsequent call transfer.
  • Page 153: Pstn Disconnect Detection Section

    Detect Disconnect Tone If enabled, SPA will disconnect both call legs when it detects the disconnect tone from the PSTN side during a gateway call. Disconnect tone is specified in the Disconnect Tone parameter, which depends on the region of the PSTN service. The default is yes. Linksys ATA Administration Guide...
  • Page 154 France—440@-30,440@-30; 2(0.5/0.5/1+2) —Impedance: 270+750||150nF Germany—425@-10; 10(0.48/0.48/1) —Impedance:220+820||120nF Netherlands—425@-30,425@-30; 2(0.5/0.5/1+2) —Impedance: 600 Sweden—425@-10; 10(0.25/0.25/1) —Impedance:600 Norway—425@-10; 10(0.5/0.5/1) —Impedance: 600 Italy—425@-30,425@-30; 2(0.2/0.2/1+2)— Impedance: 220+820||120nF Spain—425@-10; 10(0.2/0.2/1,0.2/0.2/1,0.2/0.6/1) —Impedance: 220+820||120nF Portugal—425@-10; 10(0.5/0.5/1)— Impedance:220+820||120nF Poland—425@-10; 10(0.5/0.5/1)— Impedance: n/a Denmark—425@-10; 10(0.25/0.25/1)— Impedance: 600 Linksys ATA Administration Guide...
  • Page 155: International Control (Settings) Section

    Choose from {Less than 0.5ms, 3ms (ETSI), 26ms (Australia)}. The default is Less than 0.5ms. Current Limiting Enable Enable or disable current limiting. The default is no. Ring Frequency Min Minimum ring frequency to detect. The range is 5-100. The default is 10. Linksys ATA Administration Guide...
  • Page 156: User

    When a call is made from Line 1 or Line 2, the ATA device shall use the user and line settings for that line; there is no user login support. Per user parameter tags must be appended with [1] or [2] (corresponding to line 1 or 2) in the configuration profile. It is omitted below for readability. Linksys ATA Administration Guide...
  • Page 157: Call Forward Settings Section

    The Caller number that is actively forwarded to Cfwd Last Dest by using the Call Forward Last activation code The default is blank. Cfwd Last Dest Forward number for the Cfwd Last Caller parameter. Same as Cfwd All Dest. The default is blank. Linksys ATA Administration Guide...
  • Page 158: Speed Dial Settings Section

    ATA device. The user can also manually modify it to clear or set the flag. Setting this value to yes can activate stutter tone and VMWI signal. This parameter is stored in long term memory and will survive after reboot or power cycle. The default is no. Linksys ATA Administration Guide...
  • Page 159: Distinctive Ring Settings Section

    The loopback type to use when making call to request media loopback operation. Choices are Media and Packet. Default is Media. Note that if the Linksys ATA device answers the call, then the loopback type is determined by the caller (the Linksys ATA device always picks the first loopback type in the offer if it contains multiple types.)
  • Page 160: Pstn User Page (Ag310 And Spa3102)

    VoIP number. If the caller is blocked, the SPA will not auto-answers the call. Cfwd Sel1-8 Dest Eight VoIP destinations to forward a PSTN caller matching the Cfwd Sel x Caller parameter. If this entry is blank, the PSTN caller is blocked for VoIP service. Linksys ATA Administration Guide...
  • Page 161: Pstn-To-Voip Speed Dial Settings Section

    The default ring to be used to ring through Line 1. Choose from {1,2,3,4,5,6,7,8,Follow Line 1}. If Follow Line 1 is selected, the ring to be used is determined by Line 1’s distinctive ring settings. The default is 1. Linksys ATA Administration Guide...
  • Page 162 Provisioning Reference (WRP400) The WRP400 can be provisioned remotely. This chapter provides information about the parameters that can be provisioned from an XML profile by using the Linksys profile compiler tool (SPC). NOTE:For instructions about provisioning, see the Linksys SPA Provisioning Guide (available to partners through the Linksys Partner Connection in North America and through ).
  • Page 163 The final port number in the To configure a rule for an Ethernet port: range <QOS_PRIORITY_RULE>category_num protocol : 0 (Both, 1 (TCP, 2 (UDP = 4,name= Ethernet Port 1,priority=0 </QOS_PRIORITY_RULE> To delete all rules: <QOS_PRIORITY_ RULE></QOS_PRIORITY_RULE> Linksys ATA Administration Guide...
  • Page 164 To disable Wireless Security 2: <WL_ SSID2 _mode2= [mode],[parameters]</ SECURITY_SET_1>wl1_security_mode2 <WL_SECURITY SET_2> WL_SECURITY_SET_1> =disabled</WL_SECURITY_SET_1> wl_security_mode2: Security mode for SSID1 wl1_security_mode2: Security mode for SSID2 Acceptable values are WEP, WPA Personal, WPA2 Personal, WPA Enterprise, WPA2 Enterprise, or Disabled Linksys ATA Administration Guide...
  • Page 165 To enable WPA2 Enterprise and specify wl_radius_key: RADIUS shared key; the RADIUS information: <WL_ enter from 1 to 79 ASCII characters SECURITY_ SET_1>wl_security_ wl_wpa_gtk_rekey: Key renewal mode2= wpa2_ enterprise,wl_crypto= timeout; numerals from 600 to 7200 aes,wl_radius_ipaddr=192.168.15.111, wl_radius_port=6666,wl_radius_key= enterprise,wl_wpa_gtk_rekey=666 </WL_SECURITY_SET_1> Linksys ATA Administration Guide...
  • Page 166 63 ASCII characters To configure a PPPPoE connection type and ppp_passwd: Password; enter from 1 to 63 specify a service name: <WAN_TYPE> ASCII characters wan_proto=pppoe, ppp_service: Service name; enter from 0 ppp_username=adc,ppp_passwd= to 63 ASCII characters def,ppp_service=aaa</WAN_TYPE> Linksys ATA Administration Guide...
  • Page 167 (Connect on Demand) or 0 (Keep Alive) To configure PPP to keep alive: <PPP_ DEMAND>ppp_demand=0,ppp_redial ppp_idletime: Maximum idle time in period=77</PPP_DEMAND> minutes; numerals from 1 to 9999 ppp_redialperiod: Redial period in seconds; numerals from 2 to 180 Linksys ATA Administration Guide...
  • Page 168 DNS IP address; separate multiple addresses with a space To specify multiple DNS addresses: <WAN_DNS>wan_dns=192.168.0.21 192.168.0.22</WAN_DNS> <WAN_ DNS>wan_dns=192.168.0.21 192.168.0.22 192.168.0.23</WAN_ DNS> WAN DNS, continued Fail Pattern <WAN_DNS>wan_dns=aaabbb</ WAN_DNS> <WAN_DNS>wan_dns=192.168.0.21 192.168.0.aa</WAN_DNS> <WAN_DNS>wan_dns=192.168.0.21 192.168.0.22 192.168.0.23 192.168.0.23 </WAN_DNS> Linksys ATA Administration Guide...
  • Page 169 Application name on|off: 0n (Enabled or off (Disabled both|tcp|udp: Selected protocol; tcp, udp, or both external-port: The external port number internal-port: The internal port number ip: The IP address of the PC running the specific application. Linksys ATA Administration Guide...
  • Page 170 VLAN ID number Router Syslog <ROUTER_SYSLOG>log_provision</ To configure console display and system ROUTER_SYSLOG> log: <ROUTER_SYSLOG> log_provision=2</ <ROUTER_SYSLOG> ROUTER_SYSLOG> log_provision: Type of log; 0 (console display), 1 (system log), or 2 (console display and system log) Linksys ATA Administration Guide...
  • Page 171: Troubleshooting

    9. Start Internet Explorer and enter the IP address of the ATA device. I’m trying to access the Linksys ATA administration web server, but I do not see the login screen. Instead, I see a screen saying, “404 Forbidden. ”...
  • Page 172 User account password to the default of blank. • Press 73738# to perform a full reset of unit to the defaults as it shipped from Linksys. This will reset the Admin account password to the default of blank. 3. Press 1 to confirm the operation.
  • Page 173 1. Configure your router to port forward “TCP port 80" to the IP address currently being used by your Linksys ATA device. If you do this often, we suggest that you use static IP address for the ATA device, instead of DHCP. (For help with port forwarding, consult your router documentation) 2.
  • Page 174: Pap2T

    FCC (Part 15 Class B), CE, ICES-003 Operating 32º to 113º F(0 to 45ºC) Temp Storage Temp -13º to 185ºF (-25 to 85ºC) Operating 10% to 90% relative humidity, Non-Condensing Humidity Storage 10% to 90% relative humidity, Non-Condensing Humidity Linksys ATA Administration Guide...
  • Page 175: Spa3102

    FCC (Part 15 Class B), CE, ICES-003, A-Tick Certification, RoH, UL Operating 32º to 113º F(0 to 45ºC) Temp Storage Temp -13º to 185ºF (-25 to 85ºC) Operating 10% to 90% relative humidity, Non-Condensing Humidity Storage 10% to 90% relative humidity, Non-Condensing Humidity Linksys ATA Administration Guide...
  • Page 176: Rtp300

    Operating 32º to 104º F(0 to 40ºC) Temp Storage Temp -20° C to 60° C (-4° F to 140° F) Operating 10% to 85% relative humidity, Non-Condensing Humidity Storage 5% to 90% relative humidity, Non-Condensing Humidity Linksys ATA Administration Guide...
  • Page 177: Wrtp54G

    Tick, UPnP able/cert Able, CE certification pending, Comply to RoHS Operating 32º to 104º F(0 to 40ºC) Temp Storage Temp -4º to 158ºF (-20 to 70ºC) Operating 10% to 85% relative humidity, Non-Condensing Humidity Storage 5% to 90% relative humidity, Non-Condensing Humidity Linksys ATA Administration Guide...
  • Page 178: Limited Warranty

    Your exclusive remedy and Linksysf entire liability under this limited warranty will be for Linksys, at its option, to (a) repair the product with new or refurbished parts, (b) replace the product with a reasonably available equivalent new or refurbished Linksys product, or (c) refund the purchase price of the product less any rebates.
  • Page 179: Obtaining Warranty Service

    Authorization (RMA) number. You are responsible for properly packaging and shipping your product to Linksys at your cost and risk. You must include the RMA number and a copy of your dated proof of original purchase when returning your product. Products received without a RMA number and dated proof of original purchase will be rejected.
  • Page 180: Federal Communications Commission Interference Statement

    This device must accept any interference, including interference that may cause undesired operation of the device. Règlement d’Industry Canada Cet appareil est conforme à la norme NMB003 d’Industrie Canada. Le fonctionnement est soumis aux conditions suivantes : Linksys ATA Administration Guide...
  • Page 181: Ec Declaration Of Conformity (Europe)

    Electronic Equipment (WEEE) This document contains important information for users with regards to the proper disposal and recycling of Linksys products. Consumers are required to comply with this notice for all electronic products bearing the following symbol: English - Environmental Information for Customers in the European Union European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste.
  • Page 182 Folgen für Umwelt und die menschliche Gesundheit zu vermeiden. Wenn Sie weitere Informationen zur Entsorgung Ihrer Altgeräte benötigen, wenden Sie sich bitte an die örtlichen Behörden oder städtischen Entsorgungsdienste oder an den Händler, bei dem Sie das Produkt erworben haben. Linksys ATA Administration Guide...
  • Page 183 L’élimination et le recyclage en bonne et due forme ont pour but de lutter contre l’impact néfaste potentiel de ce type de produits sur l’environnement et la santé publique. Pour plus d’informations sur le mode d’élimination de Linksys ATA Administration Guide...
  • Page 184 Ghal aktar informazzjoni dettaljata dwar ir-rimi tat-taghmir antik tieghek, jekk joghgbok ikkuntattja lill-awtoritajiet lokali tieghek, is-servizzi ghar-rimi ta’ l-iskart, jew il-hanut minn fejn xtrajt il-prodott. Magyar (Hungarian) - Környezetvédelmi információ az európai uniós vásárlók számára Linksys ATA Administration Guide...
  • Page 185 Português (Portuguese) - Informação ambiental para clientes da União Europeia A Directiva Europeia 2002/96/CE exige que o equipamento que exibe este símbolo no produto e/ou na sua embalagem não seja eliminado junto com os resíduos municipais não separados. O Linksys ATA Administration Guide...
  • Page 186 Sinun vastuullasi on hävittää tämä elektroniikkatuote ja muut vastaavat elektroniikkatuotteet viemällä tuote tai tuotteet viranomaisten määräämään keräyspisteeseen. Laitteiston oikea hävittäminen estää mahdolliset kielteiset vaikutukset ympäristöön ja ihmisten terveyteen. Lisätietoja vanhan laitteiston oikeasta hävitystavasta saa paikallisilta viranomaisilta, jätteenhävityspalvelusta tai siitä myymälästä, josta ostit tuotteen. Linksys ATA Administration Guide...
  • Page 187 Korrekt kassering och återvinning skyddar mot eventuella negativa konsekvenser för miljön och personhälsa. För mer detaljerad information om kassering av din gamla utrustning kontaktar du dina lokala myndigheter, avfallshanteringen eller butiken där du köpte produkten. Linksys ATA Administration Guide...
  • Page 188: Meaning Of The Warning Symbol

    WAN ports contain TNV circuits. Some LAN and WAN ports both use RJ-45 connectors. Use caution when connecting cables. WARNING: Equipment Installation Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Linksys ATA Administration Guide...
  • Page 189: Power Safety Information

    120 VAC, 15A U.S. (240 VAC, 10A international) WARNING: Warning Main Disconnecting Device The plug-socket combination must be accessible at all times, because it serves as the main disconnecting device. Linksys ATA Administration Guide...
  • Page 190: Software In Linksys Products

    Where such specific license terms entitle you to the source code of such software, that source code is upon request available at cost from Linksys for at least three years from the purchase date of this product and may also be available for download from www.linksys.com/gpl. For detailed license terms and additional information on open source software in Linksys products please look at the Linksys public web site at: www.linksys.com/gpl/ or Schedule 2 below as...
  • Page 191 Linksys product and/or the Software and/or your use of either in order (i) to enable Linksys to offer you Upgrades; (ii) to ensure that your Linksys product and/or the Software is being used in accordance with the terms of this Agreement;...
  • Page 192: Schedule 2

    Software Licenses: Software on a CD, Linksys will mail to You a CD with such code for $9.99 plus the cost of shipping, upon request. Term and Termination. You may terminate this License at any time by destroying all copies of the Software and documentation.
  • Page 193 Program or any derivative work under copyright law: that is to say, a work containing the Program or a portion of it, either verbatim or with modifications and/or translated into another language. (Hereinafter, translation is included without limitation in the term "modification".) Each licensee is addressed as "you". Linksys ATA Administration Guide...
  • Page 194 In addition, mere aggregation of another work not based on the Program with the Program (or with a work based on the Program) on a volume of a storage or distribution medium does not bring the other work under the scope of this License. Linksys ATA Administration Guide...
  • Page 195 Program subject to these terms and conditions. You may not impose any further restrictions on the recipients' exercise of the rights granted herein. You are not responsible for enforcing compliance by third parties to this License. Linksys ATA Administration Guide...
  • Page 196 NO WARRANTY 11. BECAUSE THE PROGRAM IS LICENSED FREE OF CHARGE, THERE IS NO WARRANTY FOR THE PROGRAM, TO THE EXTENT PERMITTED BY APPLICABLE LAW. EXCEPT WHEN OTHERWISE Linksys ATA Administration Guide...
  • Page 197 END OF TERMS AND CONDITIONS END OF SCHEDULE 2 Schedule 3 If this Linksys product contains open source software licensed under the OpenSSL license then the license terms below in this Schedule 3 will apply to that open source software. The license http://www.openssl.org/ terms below in this Schedule 3 are from the public web site at source/license.html...
  • Page 198 RC4, RSA, lhash, DES, etc., code; not just the SSL code. The SSL documentation included with this distribution is covered by the same copyright terms except that the holder is Tim Hudson (tjh@cryptsoft.com). Copyright remains Eric Young's, and as such any Copyright notices in the code are not to be removed. Linksys ATA Administration Guide...
  • Page 199 The licence and distribution terms for any publically available version or derivative of this code cannot be changed. i.e. this code cannot simply be copied and put under another distribution licence [including the GNU Public Licence.] END OF SCHEDULE 3 Linksys ATA Administration Guide...
  • Page 200 Additional support is also available by phone or online. US/Canada Contacts 24-Hour Technical Support US/Canada: 866-606-1866 Mexico: 800-314-0939 RMA (Return Merchandise Authorization) http://www.linksys.com/warranty Website http://www.linksys.com FTP Site ftp://ftp.linksys.com Support http://www.linksys.com/support Sales Information 800-546-5797 (800-LINKSYS) Global Contacts Website http://www.linksys.com/international Product Registration http://www.linksys.com/registration Linksys ATA Administration Guide...
  • Page 201 080815A-IH...

Table of Contents