Leds On The 18/4-Port Multiservice Module - Cisco AJ732A - MDS 9134 Fabric Switch Installation Manual

Cisco mds 9500 series hardware installation guide (ol-17467-02, october 2008)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 1
Product Overview
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .

LEDs on the 18/4-Port Multiservice Module

Table 1-15
Table 1-15
LED
Status Green
Link
OL-17467-02
describes the LEDs for the 18/4-port Multiservice module.
LEDs for the Cisco MDS 9000 Family 18/4-Port Multiservice Modules
Status
Description
All diagnostics pass. The module is operational (normal
initialization sequence).
Orange
One of the following occurs or occurred:
The module is booting or running diagnostics (normal
initialization sequence).
The inlet air temperature of the system exceeded the
maximum system operating temperature limit (a minor
environmental warning). To ensure maximum product
life, you should immediately correct the environmental
temperature and restore the system to normal operation.
Red
One of the following occurred:
The diagnostic test failed. The module is not operational
because a fault occurred during the initialization
sequence.
he inlet air temperature of the system exceeded the safe
T
operating temperature limits of the card (a major
environmental warning). The card shut down to prevent
permanent damage.
Solid
Link is up.
green
Solid
Link is disabled by software.
yellow
Flashing
A fault condition exists.
yellow
Off
No link.
Cisco MDS 9500 Series Hardware Installation Guide
Services Modules
1-43

Advertisement

Table of Contents
loading

Table of Contents