Appendix E
Cable and Port Specifications
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Figure E-4
a switch or hub (not provided with the switch).
Figure E-4
MGMT 10/100
Supported Power Cords and Plugs
Each power supply has a separate power cord. Standard power cords or jumper power cords are available
for connection to a power distribution unit having IEC 60320 C19 outlet receptacles. The jumper power
cords, for use in cabinets, are available as an optional alternative to the standard power cords.
Power Cords
The standard power cords have an IEC C19 connector on the end that plugs into the switch. The optional
jumper power cords have an IEC C19 connector on the end that plugs into the switch, and an IEC C20
connector on the end that plugs into an IEC C19 outlet receptacle.
Only the regular power cords or jumper power cords provided with the switch are supported.
Note
Table E-8
feet and meters.
Table E-8
Description
MDS 9513 and MDS 9509 - 3000W Power Supply
Power Cord, 125VAC 20A NEMA 5-20 Plug,
North America/Japan
Power Cord, 250VAC 16A US/Japan, Src Plug NEMA
6-20
Power Cord, 250VAC 16A US/Japan, Src Plug NEMA
L6-20
OL-17467-02
shows a schematic of the 10/100BASE-T cable required to connect the management port to
Twisted-Pair 10/100BASE-T Cable Schematic
Switch/Hub
1 TXD+
1 RXD+
2 TXD-
2 RXD-
3 RXD+
3 TXD+
6 RXD-
6 TXD-
4 NC
4 NC
5 NC
5 NC
7 NC
7 NC
8 NC
8 NC
lists the power cords for the Cisco MDS 9500 Series switches and provides their lengths in
Power Cords for the MDS 9500 Series Switches
Supported Power Cords and Plugs
Length
Feet
14
13.16
13.58
Cisco MDS 9500 Series Hardware Installation Guide
Meters
4.27
4
4.14
E-7