Chapter 2
Installing the Cisco MDS 9500 Series
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
To prevent ESD damage, wear grounding wrist straps during these procedures and handle modules by
Caution
the carrier edges only.
Install the Cisco MDS 9500 Series chassis in the rack before installing modules. See the
Note
Chassis in a Cabinet or Rack" section on page
In systems with redundant supervisor modules, you can replace the faulty supervisor while the system
Note
is operating, provided that one supervisor is always operating.

Removing Supervisor Modules

To remove a Supervisor-1 or Supervisor-2 module from the chassis, follow these steps:
Shut down the crossbar switching fabric functionality in the supervisor module of the Cisco MDS 9509
Step 1
and 9506 Directors by using the out-of-service module slot command (where slot refers to the slot
number for the Supervisor-1 or Supervisor-2 module where the integrated crossbar is located).
Upload the current configuration to a server if the switch has only one supervisor module. For
Step 2
information about the correct command, see the Cisco MDS 9000 Family CLI Configuration Guide.
Fail over to the standby supervisor if the switch has two supervisor modules and the supervisor you are
Step 3
removing is currently active. For information on how to fail over a supervisor module, see the
Cisco MDS 9000 Family CLI Configuration Guide.
Step 4
Disconnect any network interface cables attached to the module.
Step 5
Loosen the two captive screws on the module being removed.
Step 6
Remove the module from the chassis as follows:
a.
b.
Step 7
Place the module on an antistatic mat or antistatic foam, or immediately reinstall it in another slot.
Step 8
Install a filler panel on an empty slot to keep the chassis dust-free and to maintain proper airflow through
the chassis.
Warning
OL-17467-02
Place your thumbs on the left and right ejector levers and simultaneously rotate the levers outward
to unseat the module from the backplane connector.
Grasp the front edge of the module and slide the module partially out of the slot. Place your other
hand under the module to support the weight of the module. Do not touch the module circuitry.
Blank faceplates and cover panels serve three important functions: they prevent exposure
to hazardous voltages and currents inside the chassis; they contain electromagnetic
interference (EMI) that might disrupt other equipment; and they direct the flow of cooling
air through the chassis. Do not operate the system unless all cards, faceplates, front covers,
and rear covers are in place. Statement 1029