Cisco AJ732A - MDS 9134 Fabric Switch Installation Manual page 33

Cisco mds 9500 series hardware installation guide (ol-17467-02, october 2008)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 1
Product Overview
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Table 1-2
Table 1-2
LED
Input 1 OK
Input 2 OK
INPUT 1 = 220VAC
INPUT 2 = 220VAC
FAN OK
OUTPUT FAIL
OL-17467-02
describes the LEDs for the Cisco MDS 9513 Director power supplies.
LEDs for the Cisco MDS 9513 Director Power Supplies
Status
Green
Off
Green
Off
Green
Off
Green
Off
Green
Off
Red
Off
Description
AC input at greater than 85 V is good and power
supply is functioning normally if two single 110 V
or one single 220 V are connected.
Power supply is turned off or power is not
connected.
AC input at greater than 85 V is good and power
supply is functioning normally if two single 110 V
or one single 220 V are connected.
Power supply is turned off or power is not
connected.
AC input is good at greater than 168 V and power
supply should function normally.
AC input is 163 V or less or power is not
connected.
AC input is good at greater than 168 V and power
supply should function normally.
AC input is 163 V or less or power is not
connected.
Power supply fans are operating properly.
Fan is not operating or power supply is off.
Power supply is not in a stable state. If this
indication continues after initial power on, check
that all connections are secure, including the
system fan tray.
Normal operation or power supply is turned off.
Cisco MDS 9500 Series Hardware Installation Guide
Power Supplies
1-11

Advertisement

Table of Contents
loading

Table of Contents