Cisco AJ732A - MDS 9134 Fabric Switch Installation Manual page 129

Cisco mds 9500 series hardware installation guide (ol-17467-02, october 2008)
Hide thumbs Also See for AJ732A - Cisco MDS 9134 Fabric Switch:
Table of Contents

Advertisement

Chapter 2
Installing the Cisco MDS 9500 Series
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m .
Open both the ejector levers on the new or replacement module completely.
Step 2
Position the module in the chassis as follows:
Step 3
a.
b.
Figure 2-26
c.
Caution
d.
OL-17467-02
Position the module in the slot. Ensure that you align the sides of the module carrier with the slot
guides on each side of the slot.
Slide the module carefully into the slot until the EMI gasket along the top edge of the module
contacts the module in the slot above it and both ejector levers close to approximately 45 degrees
with respect to the front of the module. (See
Installing the Crossbar Module
Grasp the two ejector levers using the thumb and forefinger of each hand, and press down to create
a small 0.040-inch (1-mm) gap between the module's EMI gasket and the module above it.
Do not press down too forcefully on the levers because they can bend.
While pressing down, simultaneously close the top and bottom ejector levers to completely seat the
module in the midplane connector. The ejector levers are completely closed when they are flush with
the front of the module.
Removing, Installing, and Verifying Supervisor, Switching, and Services Modules
Figure
2-26.)
Cisco MDS 9500 Series Hardware Installation Guide
2-49

Advertisement

Table of Contents
loading

Table of Contents