Coaxial Cable Installation

Procedure: Install Coaxial Cable With High-Density BNC Connectors

Step 1
Place the BNC cable connector over the desired connection point on the backplane.
Step 2
Using the insertions tool, position the cable connector so that the slot in the connector is over the
corresponding notch at the backplane connection point.
Step 3
Gently push the connector down until the notch backplane connector slides into the slot on the cable
connector.
Step 4
Turn the cable connector until the notch clicks into place.
Step 5
Tie wrap or lace the cables to the EIA according to Telcordia standards (GR-1275-CORE) or local site
practice.
Step 6
Route the cables to the nearest side of the shelf assembly through the side cutouts according to local site
practice.
The rubber coated edges of the side cutouts prevent the cables from chafing.

1.10.3 SMB Connector Installation

The SMB backplane cover is similar to the BNC cover. For further detail, see the
on page
Right-angle mating connectors for the connecting cable are AMP 415484-2 (75 Ohm) connectors. Use
RG-179/U cable to connect to the ONS 15454 EIA. Cisco recommends these cables for connection to a
patch panel; they are not designed for long runs (over 50 feet). Range does not affect loopback testing.
For information about attaching ferrites to SMB/BNC connectors, see the
on page

Procedure: Install Coaxial Cable with SMB Connectors

Refer to
Place the SMB cable connector over the desired connection point on the backplane.
Step 1
Gently push the connector until it clicks into place.
Step 2
Step 3
Tie wrap or lace the cables to the EIA according to Telcordia standards (GR-1275-CORE) or local site
practice.
Route the cables to the nearest side of the shelf assembly into rack runs according to local site practice.
Step 4
Cisco ONS 15454 Installation and Operations Guide
1-38
1-19. The SMB connectors on the EIA are AMP 415504-3 (75 Ohm) 4 leg connectors.
1-61.
Figure 1-26
when performing the following steps.
Chapter 1
Hardware Installation
"SMB EIA" section
"Ferrite Installation" section
November 2001