Chapter 7
Card Provisioning
Table 7-5
Subtab
Elect Path
Thrshld
November 2001
DS3XM-6 Parameters (continued)
Parameter
Description
CV
Coding violations
ES
Errored seconds
SES
Severely errored seconds
SAS
Severely errored frame/alarm
indication Signal
AIS
Alarm indication signal
UAS
Unavailable seconds
Options
Numeric. Defaults (DS3, Pbit Near
End only; DS3 CPbit, Near and Far
End):
382 (15 minutes)
•
•
3820 (1 day)
Numeric. Defaults (15 min/1 day):
•
25/250 (DS3 Pbit Near End only;
DS3 CPbit, Near and Far End)
•
65/648 (DS1, Near End only)
Numeric. Defaults (15 min/1 day):
4/40 (DS3 Pbit Near End only;
•
DS3 CPbit, Near and Far End)
10/100 (DS1, Near End only)
•
Numeric. Defaults (15 min/1 day):
2/8 (DS3 Pbit Near End only; DS3
•
CPbit, Near and Far End)
2/17 (DS1, Near End only)
•
Numeric. Defaults (15 min/1 day):
•
10/10 DS1, Near End; DS3, Near
& Far End
0/0 DS1 Far End
•
Numeric. Defaults (15 min/1 day):
•
10/10 (DS3 Pbit Near End only;
DS3 CPbit, Near and Far End)
•
10/10 (DS1, Near End only)
Cisco ONS 15454 Installation and Operations Guide
Provisioning Electrical Cards
7-13