Provisioning Electrical Cards
Table 7-4
Subtab
Line Thrshold
Elect Path
Thrshld
Cisco ONS 15454 Installation and Operations Guide
7-10
DS3E Card Parameters (continued)
Parameter
Description
CV
Coding violations
ES
Errored seconds
SES
Severely errored seconds
LOSS
Loss of signal; number of
one-second intervals containing
one or more LOS defects
CV
Coding violations
ES
Errored seconds
SES
Severely errored seconds
SAS
Severely errored frame/Alarm
indication signal
AIS
Alarm indication signal
UAS
Unavailable seconds
Chapter 7
Card Provisioning
Options
Numeric. Defaults:
• 387 (15 minutes)
• 3865 (1 day)
Numeric. Defaults:
• 25 (15 minutes)
• 250 (1 day)
Numeric. Defaults:
•
4 (15 minutes)
•
40 (1 day)
Numeric. Defaults:
10 (15 minutes)
•
10 (1 day)
•
Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
382 (15 minutes)
•
3820 (1 day)
•
Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
•
25 (15 minutes)
•
250 (1 day)
Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
•
4 (15 minutes)
•
40 (1 day)
Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
•
2 (15 minutes)
8 (1 day)
•
Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
10 (15 minutes)
•
10 (1 day)
•
Numeric. Defaults (DS3 Pbit, Near End
only; DS3 CPbit, Near and Far End):
10 (15 minutes)
•
•
10 (1 day)
November 2001