User Parameter Sets; User Lock - ABB ACQ80 Firmware Manual

Standard program control
Table of Contents

Advertisement

User parameter sets

The drive supports four user parameter sets that can be saved to the
permanent memory and recalled using drive parameters. It is also possible to
use digital inputs to switch between user parameter sets. To change a user
parameter set, make sure the drive is not modulating.
A user parameter set contains all editable values in parameter groups 10...99
except the following:
• forced I/O values such as parameters
forced data
• I/O extension module settings (group 15)
• fieldbus communication settings (groups 50...53 and 58)
• parameter
95.01 Supply
As the motor settings are included in the user parameter sets, make sure the
settings correspond to the motor used in the application before recalling a user
set. In an application where different motors are used with the drive, perform
the motor ID run with each motor and the save the results in different user sets.
The appropriate set can then be recalled when the motor is switched on.
Settings and diagnostics
Parameters:
10.03 DI force selection...10.04 DI forced data
(page 246) and
Supply voltage
(page 254)
Event:
64B2 User set fault

User lock

For better cyber security, it is highly recommended that you set a master pass
code to prevent changing of parameter values and/or the loading of firmware
and other files.
WARNING! ABB will not be liable for damages or losses caused by the
failure to activate the user lock using a new pass code. See
marked on the type designation label attached to the drive, see section Type
designation label in the hardware manual of the drive.
To activate the user lock for the first time:
• Enter the default pass code, 10000000, into
parameters
96.100...96.102
• Enter a new pass code into
digits, if using Drive composer PC tool. Finish with Enter.
• Confirm the new pass code in
10.03 DI force selection
voltage.
96.10 User set status...96.13 User set I/O mode in1
(page 331).
visible.
96.100 Change user pass
96.101 Confirm user pass
Program features 69
and
(page 101),
code. This will make
96.02 Pass
code. Always use eight
code.
10.04 DI
95.01
The frame is

Advertisement