ABB ACQ80 Firmware Manual page 187

Standard program control
Table of Contents

Advertisement

No.
Name/Value
36.06
AL2 signal
source
36.07
AL2 signal
scaling
0.00...32767.00
36.09
Reset loggers
Done
All
PVL
AL2
36.10
PVL peak value
-32768.00...
32767.00
36.11
PVL peak date
1/1/1980...
6/5/2159
36.12
PVL peak time
-
Description
Selects the signal to be monitored by amplitude
logger 2. The signal is sampled at 200 ms
intervals.
The results are displayed by parameters
36.49. Each parameter represents an amplitude
range, and shows what portion of the samples
fall within that range.
The signal value corresponding to 100% is
defined by parameter
Amplitude logger 2 can be reset using parameter
loggers. The date and time of the last
36.09 Reset
reset are stored into parameters
respectively.
For the selections, see parameter
signal
source.
See parameter
36.01
Defines the monitored signal value for the
amplitude logger AL2 that corresponds to 100%
sample value.
Signal value corresponding to 100%.
Resets the peak value logger and/or amplitude
logger 2. (Amplitude logger 1 cannot be reset.)
Reset completed or not requested (normal
operation).
Reset both the peak value logger and amplitude
logger 2.
Reset the peak value logger.
Reset amplitude logger 2.
Shows the peak value recorded by the peak value
logger.
Peak value.
Shows the date when the peak value was
recorded.
Peak occurrence date.
Shows the time when the peak value was
recorded.
Peak occurrence time.
36.40
36.07 AL2 signal
scaling.
and
36.50
36.01 PVL
for the selections.
Parameters 187
Def/
FbEq16
Motor
torque
...
36.51
100.00
1 = 1
Done
0
1
2
3
0.00
1 = 1
01/01/
1980
-
00:00:00
-