Informational Messages, Severity Level 6
Error Message %LOCAL7-6-SM_TAKEOVER: "Redundancy: SM connection status is up while
down in peer box."
Explanation
due to the session timeout. The connection status is verified in the cascade connection when one of
the Cisco SCE platforms has the Subscriber Manager connection and tries to verify another Cisco
SCE platform connection.
Recommended Action
Error Message %LOCAL7-6-SYSTEM_CHANGE_TO_STANDBY: "Redundancy: User request -
changed system to standby."
Explanation
has changed from the active state to the standby state.
Recommended Action
Error Message %LOCAL7-6-FOUND_NO_IMPROPER_CONNECTIONS :
"RedundancyManager:Previously found improper cascade connections are now
fixed/disconnected."
Explanation
the Remote Procedure Call (RPC) layer.
Recommended Action
Error Message %LOCAL7-6-NOTIFY_USER_EVENT_ON: "Started filtering packets of type
'%s' received on interface # %d (<%s>). module # %d. Reason
Explanation
given types of packets on the corresponding interface.
Recommended Action
Error Message %LOCAL7-6-NOTIFY_USER_EVENT_OFF: "Stopped filtering packets of type
'<%s>' received on interface # %d (<%s>). module # %d. Reason
Explanation
given type of packets on the corresponding interface.
Recommended Action
Error Message %LOCAL7-6-UNFORCE_LINK_DOWN: "Link on port %d is unforced down."
Explanation
Recommended Action
Cisco SCE8000 GBE Installation and Configuration Guide
C-38
This message is displayed to indicate that the Subscriber Manager connection is down
None.
In the cascade state machine, this message is displayed to indicate that the system state
None.
This message is displayed to indicate that no improper connections are indicated from
None.
This message indicates that the attack filter event has occured and starts filtering the
None.
This message indicates that an attack filter event has occurred, and stops filtering the
None.
This message is displayed when the link on a specific port is in the unforced down state.
None.