Information About Troubleshooting Tools
Table 8-2
Cisco SCE 8000 Operational States (continued)
Cisco SCE 8000
Operational Status
Warning
Failure
Table 8-3
LED Label
INPUT OK
OUTPUT FAIL
FAN OK
Power (front
panel)
Cisco SCE8000 GBE Installation and Configuration Guide
8-6
Description
Cisco SCE 8000 is fully operational (as above) but one of the
following occurred:
GBE Management port link is down.
Internal temperature above threshold.
Internal voltage not in expected range.
Fan problem.
Power supply problem.
Insufficient space on the disk.
If the condition that caused the Cisco SCE 8000 to be in
Note
Warning state is resolved (for example, link is up) the
Cisco SCE 8000 reverts to Operational state.
System is in Failure state after Boot because of one of the
following conditions:
Power-on test failure.
Three abnormal reboots in less than 30 minutes.
Platform configured to enter Failure mode consequent to
failure-induced reboot (this is configurable using CLI
command).
Severe system health problem, such as extensive overheating
or voltage out of correct operating range.
Note
Depending on the cause of failure, the management
interface and the platform configuration may or may not be
active/available.
Power Supply LEDs
Color
Green
Green
Green
Green
State
Function
On
Input voltage is present and within the required
range.
Off
Input voltage is not present or not within the required
range.
On
Output voltage is not within the required range.
Off
Output voltage is in the required range.
On
Power supply internal fan is operational.
Off
Power supply internal fan is not operational.
Steady
Installed power supplies are functioning normally.
Chapter 8 Troubleshooting
Status LED State
Flashing amber
Red