Cascaded Systems; How To Install A Cascaded System; Cli Commands For Cascaded Systems - Cisco SCE 8000 Installation And Configuration Manual

10 gbe
Hide thumbs Also See for SCE 8000:
Table of Contents

Advertisement

Chapter 6 Cabling the Line Ports and Completing the Installation

Cascaded Systems

This section contains the following topics:

How to Install a Cascaded System

This section outlines the installation procedures for a redundant solution with two cascaded
Cisco SCE 8000 platforms. See the Cisco SCE8000 CLI Command Reference for details of the CLI
commands.
When working with two Cisco SCE 8000 platforms with split-flow and redundancy, it is extremely
important to follow this installation procedure.
Install both Cisco SCE 8000 platforms, power them up, and perform the initial system configuration.
Step 1
(See
Interfaces"and the
To maintain link continuity at all times, including during the reload sequence and power failure events,
it is recommended to install optical bypass modules.
Connect both Cisco SCE 8000 platforms to the management station. (See
Step 2
Interfaces, page
Step 3
Connect the cascade ports. (See
The cascade ports must be either be connected directly in Layer 1 (dark fibers), or using the following
procedure to connect through a switch:
a.
b.
Set topology configurations for each Cisco SCE 8000 platform via the connection-mode options. (See
Step 4
How to Configure the Connection Mode, page
Make sure that the Cisco SCE 8000 platforms have synchronized and the active Cisco SCE 8000
Step 5
platform was selected.
Use the show interface linecard 0 connection-mode command.
If you want to start with bypass, change the link mode to your required mode in both Cisco SCE 8000
Step 6
platforms on both links. The bypass mode is applied only to the active Cisco SCE 8000 platform. (See
How to Set the Link Mode, page
Step 7
Ensure that the link mode complies with what you required. (See
page
Use the show interface linecard 0 link mode command.
Step 8
Connect the traffic port of Cisco SCE 8000 platform 1. This causes a momentary down time until the
network elements from both sides of the Cisco SCE 8000 platform auto-negotiate with it and starts
working (when working inline). (See
How to Install a Cascaded System, page 6-19
CLI Commands for Cascaded Systems, page 6-20
Chapter 4, "Installing the Cisco SCE 8000
"Starting the Cisco SCE 8000 Platform" section on page
5-5.)
Connect port 3/2/0 from box A and port 3/3/0 from box B to a single switch. Configure them both
on the same access VLAN, which is used only by the interfaces connected to these ports. No other
interfaces in the switch should reside on that VLAN.
Connect port 3/3/0 from box A and port 3/2/0 of box B to a switch on a different VLAN. Again, the
access ports should be configured as access ports on this VLAN, which are used only by the
interfaces connected to these ports. No other interfaces in the switch reside on the VLAN.
6-22.)
Chassis"and
Dual Link: Two Cisco SCE 8000s Topology, page
6-21.)
6-21.)
Dual Link: Two Cisco SCE 8000s Topology, page
Cisco SCE8000 GBE Installation and Configuration Guide
Cascaded Systems
Chapter 5, "Connecting the Management
7-2.)
Connecting the Management
6-3.)
Monitoring a Cascaded System,
6-3.)
6-19