Sony FVS-1000 System Maintenance Manual page 79

Multi resolution film scanner, multi resolution telecine, telecine processor, telecine hdtv/sdtv processing boards, telecine log data processor, telecine 16 mm film adaptor kit, telecine optical kit, telecine mounted slide kit, telecine film sound process
Hide thumbs Also See for FVS-1000 System:
Table of Contents

Advertisement

No.
Sensor
1
Front internal lock SW
2
S side tension regulator potential meter
3
S tension regulator position sensor
4
S side reel A/B winding SW
5
Lens emergency
6
Gate (retainer) discrimination SW
7
S side PAD roller position sensor
8
S side PT roller position sensor
9
A side PAD TYPE SW
!/
Electrostatic sensor
!-
Gate TYPE SW
!=
Slide adaptor detection SW
![
Mirror
!]
Gate position sensor
!\
T side tension regulator potential meter
!;
T side tension regulator position sensor
!'
T side reel A/B winding SW
!,
Lens emergency (LED)
!.
OPS H direction glass sensor
@/
OPS V direction glass sensor
@-
T side PAD roller position sensor
@=
T side PT roller position sensor
@[
T side PAD TYPE SW
@]
Integral ball discrimination sensor
@\
Lamp SW
@;
STANDBY SW
@'
SV RESET SW
@,
Breaker
@.
Rear internal lock SW
#/
Lens load SW
#-
Imager movement table position sensor
#=
Loop sensor
FVS-1000 MMP1
@.
#-
#/
Rear side
Function
The power is turned on by closing the front door.
This meter detects the rotation angle of the S side tension regulator arm.
This sensor detects load and unload position of S tension regulator.
This switches A/B winding at the S side reel.
This detects the lens position. (Photo-diode)
This switch discriminates between 16 mm and 35 mm of the gate.
This sensor detects load and unload position of the S side PAD roller.
This sensor detects load and unload position of the S side PT roller.
This switch discriminates between 16 mm and 35 mm of the S side PAD roller and
detects whether the S side PAD roller is installed or not.
This sensor detects the film (perforations) position.
This switch discriminates between 16 mm and 35 mm of the gate and detects whether
the gate is installed or not.
This switch detects the slide adaptor.
This sensor detects the load and unload position of the gate (retainer).
This meter detects the rotation angle of the T side tension regulator arm.
This sensor detects the load and unload position of the T side tension regulator.
This switches A/B winding at the T side reel.
This detects the lens position.
This sensor detects the glass position in the horizontal direction of the OPS.
This sensor detects the glass position in the vertical direction of the OPS.
This sensor detects load and unload position of the T side PAD roller.
This sensor detects load and unload position of the T side PT roller.
This switch discriminates between 16 mm and 35 mm of the T side PAD roller and
detects whether the S side PAD roller is installed or not.
This sensor discriminates among 16 mm, 35 mm and 8P of the integral ball.
Emergency switch to turn off the lamp
Switch for STANDBY
Switch for servo reset
Switch to turn on or off the system
When replacing the lens, the power is turned off by opening the rear door.
When replacing the lens, the lens can be moved.
This sensor detects whether the imager movement table is pulled out or not.
For detecting the loop amount between the sprockets.
2-3. Location of Main Parts
2-11

Advertisement

Table of Contents
loading

Table of Contents