(6) Loosen the lock screw, then insert the control panel.
9. Installation of the OPS assembly
(1) Pull the OPS cover toward you, then remove from the base plate.
(2) Pass the reference pins through the holes on the OPS assembly and OPS support plate, then fix it with
the supplied four screws (M3 x 6) .
(3) Connect the connector of the base plate with CN1 on the SE-515 board.
(4) Adjust the hole at the rear of the OPS cover to the OPS support, push in the OPS support completely,
and install to the base plate.