Sony FVS-1000 System Maintenance Manual page 222

Multi resolution film scanner, multi resolution telecine, telecine processor, telecine hdtv/sdtv processing boards, telecine log data processor, telecine 16 mm film adaptor kit, telecine optical kit, telecine mounted slide kit, telecine film sound process
Hide thumbs Also See for FVS-1000 System:
Table of Contents

Advertisement

6-6. Lamp House Adjustment
Gain Adjustment
1. Connect the oscilloscope to the following TPs, and
adjust so that the waveform satisfies the specification.
LC-35 board No. suffix -13 and higher
Measuring point
Adjustment RV
TP704/LC-35(A-2)
RV702/LC-35(A-2)
Connect GND to E2/LC-35(A-1)
LC-35 board No. suffix -12
Measuring point
Adjustment RV
TP400/LC-35(A-2)
RV401/LC-35(B-3)
Connect GND to E101/LC-35(A-3)
Specification:
A = Minimum
A
2. Check the light amount satisfies the specification in
the procedure of light amount adjustment steps 4 and
5.
When the above is not satisfied, perform the adjusting
procedure of the light amount and gain again.
3. Set a unit to the initial state in the reverse procedure of
preparations steps 1 to 6.
A
B
C
1
E2
RV461
RV431
RV401
RV701
2
RV702
TP704
3
TP305
TP303 TP301
4
5
LC-35 board (Suffix -13 and higher, Side A)