Identifier=value
Table 4-22
The following target areas are supported:
Target area
Archive
NCU / PPU
PCU 50 (Win 7)
Operate
Note
Selected data areas define target areas
Which target areas are displayed depends on the data areas (archive, PCU, NCU/PPU) that
were activated for use.
The data areas are defined in the project folder in the Package tab (Page 137).
If a data area is subsequently deactivated, then all of the target area nodes that cannot be
hidden due to content are shown in red.
Note
Display of the target area
● Gray - target area does not contain any data.
● Red - data in the target area is not used.
● Blue - linked data with resolution for deployment.
To enter change instructions, use the context menu to create a "task" in the folder that contains
the file to be changed.
The name and path of a task specify the file to be changed.
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 12/2017, A5E36537479B-AE
Description
Archive image
NCU/PPU CF card
PCU drives/shares
SINUMERIK Operate folder
Create MyConfig - Expert
4.5 Component editor
Example
NC, MMC, NC_MMC, PLC, CP, DRV
user, oem, addon
C:, D:
hmisl or card