9.4

Message buffer

In addition to the fault buffer for F... faults and the alarm buffer for A... alarms (see the
relevant section in: /IH1/ SINAMICS S120 Commissioning Manual), a special message
buffer for C... safety messages is available for Safety Integrated Extended Functions.
The fault messages for the Safety Integrated Basic Functions are stored in the standard fault
buffer (see Section "Buffer for faults and alarms" in /IH1/: SINAMICS S120 Commissioning
Manual).
Not e
Mes sages of the B asic and t he Extended Functions
Set parameter p3117 = 1 if you need to save both the Basic Functions messages and the
Extended Functions messages in the standard fault buffer.
The message buffer for safety messages is similar to the fault buffer for fault messages. The
message buffer comprises the message code, message value, and message time (received,
resolved), the component number for identifying the affected SINAMICS component and
diagnostics attributes. The following diagram shows how the message buffer is structured:
Image 9-1
Structure of the message buffer
Safety Integrated
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6