Mitsubishi Electric MELSEC iQ-R Series User Manual page 81

Simple motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

[Cd.601] to [Cd.607] Cam data
[Cd.600] Cam data operation
request
■Auto-generation data format [RD77GF]
When the reading (cam storage area) is executed to the cam data created with the cam auto-generation or the cam data
created with the cam curve by the engineering tool, the data is read as auto-generation data format.
• Cam for rotary cutter (central reference) data
• Easy stroke ratio cam data
• Advanced stroke ratio cam data
For the buffer memory assignment at reading, refer to the following.
Page 82 [Cd.611] Cam auto-generation data
However, cam data created by a free-form curve cannot be read.
Not set
Set
0
2
0
3 CAM FUNCTION
79
3.2 Create Cam Data
3

Advertisement

Table of Contents