Mitsubishi Electric MELSEC iQ-R Series User Manual page 171

Simple motion module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Ex.
When "[Cd.617] Cam position calculation: Cam axis position value per cycle" is corresponding to the 1st point of cam data
Search starting point
At the 1st point
At the 0th point
0
(Cam reference
position)
(1)
• Searches until between the 4th point and the 5th point (last point) in order of the cam data between the 1st point and the
2nd point and between the 2nd point and the 3rd point.
• If the corresponding position is not found until the last point of the cam data, searches from the range of (3).
Ex.
When "[Cd.617] Cam position calculation: Cam axis position value per cycle" is corresponding to the 3rd point of cam data
[Cd.617] Cam position calculation:
At the 0th point
Cam axis position value
per cycle
0
(Cam reference
position)
(1)
• Searches in order of the cam data between the 3rd point and the 4th point and between the 4th point and the 5th point (last
point).
• If the corresponding position is not found until the last point of the cam data, searches from the 1st point of the cam data.
• If the corresponding position is not found in the cam data between the 1st point and the 2nd point and between the 2nd
point and the 3rd point, searches from the range of (3).
1
At the 2nd point
[Cd.617] Cam position
calculation: Cam axis
position value per cycle
(2)
Cam axis length per cycle [Cam axis cycle units]
2
At the 2nd point
At the 1st point
At the 3rd point
(2)
Cam axis length per cycle [Cam axis cycle units]
At the 3rd point
At the 5th point
At the 4th point
1
Search starting point
At the 5th point
At the 4th point
5 ADVANCED SYNCHRONOUS CONTROL INITIAL POSITION
5.5 Cam Position Calculation Function
2
Search order
(3)
3
Search order
(3)
5
169